Maximum Allowable TCF Calibration Error for Robotic Pose Servoing

Robotic pose servoing aims to move the robot end-effector to the target pose. Closed-loop servo systems can tolerate a small TCF (tool control frame) calibration error and accurately reach the target pose through multiple pose measurements and pose adjustments. However, the maximum allowable TCF calibration error remains an open question. This paper demonstrates that the necessary condition for robotic pose servoing is a TCF calibration error angle of less than 60 degrees, with no limit on the translational component of the TCF calibration error. Next, an improved pose servoing method is proposed to address the conflict between the large TCF error and the limited robot workspace. This method introduces a scaling factor to limit the adjustment range within the robot workspace, ensuring greater robustness. Finally, robot-assisted cabin docking is selected as an experimental validation case. Simulation and physical experiments validate the maximum allowable TCF calibration error. Comparative experiments confirm the robustness of the improved pose servoing method, achieving cabin docking despite significant TCF calibration errors.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2024-12-25
DOI
https://doi.org/10.1109/lra.2024.3522840
Citations
2
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maximum Allowable TCF Calibration Error for Robotic Pose Servoing

Jun Hou, Min Tan, Shiyu Xing, Yunkai Ma et al.
2 citations
IEEE Robotics and Automation Letters
Robotic Mechanisms and Dynamics
0.66
article

Maximum Allowable TCF Calibration Error for Robotic Pose Servoing

Jun Hou, Min Tan, Shiyu Xing, Yunkai Ma, Fengshui Jing
article en
2 citations

Abstract

Robotic pose servoing aims to move the robot end-effector to the target pose. Closed-loop servo systems can tolerate a small TCF (tool control frame) calibration error and accurately reach the target pose through multiple pose measurements and pose adjustments. However, the maximum allowable TCF calibration error remains an open question. This paper demonstrates that the necessary condition for robotic pose servoing is a TCF calibration error angle of less than 60 degrees, with no limit on the translational component of the TCF calibration error. Next, an improved pose servoing method is proposed to address the conflict between the large TCF error and the limited robot workspace. This method introduces a scaling factor to limit the adjustment range within the robot workspace, ensuring greater robustness. Finally, robot-assisted cabin docking is selected as an experimental validation case. Simulation and physical experiments validate the maximum allowable TCF calibration error. Comparative experiments confirm the robustness of the improved pose servoing method, achieving cabin docking despite significant TCF calibration errors.

IEEE Robotics and Automation LettersVol. 10(2)
Chinese Academy of Sciences (CN), Shandong Institute of Automation (CN), Institute of Automation (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 28%
Robotic Mechanisms and Dynamics
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Maximum Allowable TCF Calibration Error for Robotic Pose Servoing — Jun Hou, Min Tan, et al. · IEEE Robotics and Automation Letters (2024) | TGRS Research Map | TGRS