1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line

The transition resistance during single-phase grounding faults in transmission lines is closely related to the fault cause. Quickly determining the cause of the fault through the transition resistance value and taking targeted measures to restore the power supply quickly is of great significance to improving the stability of the power system. Starting from the basic circuit principle, this paper analyzes the composition of the transition resistance for two typical grounding situations: the line-to-tower discharge and the line-to-ground discharge, and derives the equivalent impedance of the tower-wire grounding system. Based on analyzing the grounding wire parameters, the tower grounding resistance, and the span size, the 1-ohm impedance criterion was proposed, that is, the transition resistance during line-to-tower discharges should be less than 1 ohm. Then, the equation for calculating the transition resistance using the double-terminal fault recording was derived and simplified for engineering calculation. Finally, combined with 56 real fault cases of 220 kV~1000 kV transmission lines, each case’s transition resistance value and fault cause are analyzed to verify the effectiveness of the proposed 1-ohm criterion.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2024-12-25
DOI
https://doi.org/10.1109/access.2024.3523266
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line

Xueming Zhou, Xiankang Wang, Zijian Li, Zixuan Hu et al.
1 links
IEEE Access
Power Systems and Technologies
article

1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line

Xueming Zhou, Xiankang Wang, Zijian Li, Zixuan Hu, Zhi‐Qiang Feng, Yao Yao, Jianjin Fu
article en

Abstract

The transition resistance during single-phase grounding faults in transmission lines is closely related to the fault cause. Quickly determining the cause of the fault through the transition resistance value and taking targeted measures to restore the power supply quickly is of great significance to improving the stability of the power system. Starting from the basic circuit principle, this paper analyzes the composition of the transition resistance for two typical grounding situations: the line-to-tower discharge and the line-to-ground discharge, and derives the equivalent impedance of the tower-wire grounding system. Based on analyzing the grounding wire parameters, the tower grounding resistance, and the span size, the 1-ohm impedance criterion was proposed, that is, the transition resistance during line-to-tower discharges should be less than 1 ohm. Then, the equation for calculating the transition resistance using the double-terminal fault recording was derived and simplified for engineering calculation. Finally, combined with 56 real fault cases of 220 kV~1000 kV transmission lines, each case’s transition resistance value and fault cause are analyzed to verify the effectiveness of the proposed 1-ohm criterion.

IEEE AccessVol. 13
Electric Power Research Institute (US), North China Electric Power University (CN)
Science and Technology Project of State Grid
Climate action
Openalex Percentile: Top 78%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

1-ohm Impedance Criterion for Diagnosis of Single-Phase Ground Fault of Transmission Line — Xueming Zhou, Xiankang Wang, et al. · IEEE Access (2024) | TGRS Research Map | TGRS