Measurement of a high numerical aperture spherical mirror using a Computer-Generated hologram

• Optical measurement of a NA0.92 spherical concave mirror using a Computer-Generated Hologram (CGH) • CGH fabrication error calibration using the smallest random ball test and its compensation method. • Calibration of interferometric imaging distortion error using a THz wire grid polarizer. • Measurement result comparison between a conventional stitching method and the proposed CGH method. High precision and high numerical aperture (NA) spherical concave mirror is used as a metrology reference for lithography and spectroscopy optics at UV and X-ray wavelengths. We propose to use a computer-generated hologram (CGH) for optical testing of a reference sphere (RS) with an NA of 0.92 as a less time- and effort-intensive alternative to the conventional sub-aperture stitching method. We experimentally obtained the CGH error using the random ball test (RBT) for the first time to our knowledge. We used a spherical ball with a diameter of 3.175 mm, the smallest ball utilized for RBT reported to date. We experimentally verified that the thickness deviation of the CGH substrate due to the fabrication error induces spherical aberration (SA) that can be effectively compensated by defocusing the CGH position at a predefined amount. We also propose to use a THz wire grid polarizer as a distortion reference for the distortion error calibration of an interferometric imaging system. We verified this measurement method for the RS NA 0.92 and compared the result with the conventional stitching method. The results from both testing approaches produced similar surface error maps, thus verifying each approach’s result. But, the single full aperture measurement using a CGH is found to be more efficient for measuring a high NA reference sphere.

Authors

Institutions

Publication Details

Journal
Measurement
Published
2024-12-25
DOI
https://doi.org/10.1016/j.measurement.2024.116591
Citations
2
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of a high numerical aperture spherical mirror using a Computer-Generated hologram

Hagyong Kihm, Ma. Angela Lourdes B. Lequiron, Ho-Soon Yang, Jae-Hyuck Choi
2 citations
Measurement
Optical measurement and interference techniques
0.50
article

Measurement of a high numerical aperture spherical mirror using a Computer-Generated hologram

Hagyong Kihm, Ma. Angela Lourdes B. Lequiron, Ho-Soon Yang, Jae-Hyuck Choi
article en
2 citations

Abstract

• Optical measurement of a NA0.92 spherical concave mirror using a Computer-Generated Hologram (CGH) • CGH fabrication error calibration using the smallest random ball test and its compensation method. • Calibration of interferometric imaging distortion error using a THz wire grid polarizer. • Measurement result comparison between a conventional stitching method and the proposed CGH method. High precision and high numerical aperture (NA) spherical concave mirror is used as a metrology reference for lithography and spectroscopy optics at UV and X-ray wavelengths. We propose to use a computer-generated hologram (CGH) for optical testing of a reference sphere (RS) with an NA of 0.92 as a less time- and effort-intensive alternative to the conventional sub-aperture stitching method. We experimentally obtained the CGH error using the random ball test (RBT) for the first time to our knowledge. We used a spherical ball with a diameter of 3.175 mm, the smallest ball utilized for RBT reported to date. We experimentally verified that the thickness deviation of the CGH substrate due to the fabrication error induces spherical aberration (SA) that can be effectively compensated by defocusing the CGH position at a predefined amount. We also propose to use a THz wire grid polarizer as a distortion reference for the distortion error calibration of an interferometric imaging system. We verified this measurement method for the RS NA 0.92 and compared the result with the conventional stitching method. The results from both testing approaches produced similar surface error maps, thus verifying each approach’s result. But, the single full aperture measurement using a CGH is found to be more efficient for measuring a high NA reference sphere.

MeasurementVol. 245
Korea Research Institute of Standards and Science (KR), Korea University of Science and Technology (KR)
Openalex Percentile: Top 32%
Optical measurement and interference techniques
0.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.