Development and exergo-energetic analysis of an energy-efficient solar-assisted transcritical CO2 refrigeration system with two-phase ejector

• A new solar-assisted vapor compression/ejector refrigeration system using R744 as the working fluid was developed and analyzed. • The ejector performance and the energy and exergy analysis of the system were evaluated. • The COP and energy saving values of the system for a solar irradiation of 300W/m 2 are 2.88 and 30%, respectively. • The COP reaches a value of 3.4 for an evaporation temperature of 5 °C. • The PTC is the system component that destroys the most exergy, followed by the compressor, the ejector and the gas cooler. This paper proposes and evaluates the performance of a new refrigeration and energy production system that combines the vapor compression cycle with ejector and the Brayton subcycle using CO 2 as the working fluid. In this system, the Brayton cycle uses solar radiation as thermal energy, the heat of which is transmitted to the fluid through a solar concentrator, then expanded in a turbine to produce mechanical energy favorable to the reduction of energy consumed by the compressor of the refrigeration cycle. The study aims to examine the energy and exergy performance criteria of the combined system. The developed model of the system was simulated using EES software, for an evaporation temperature of −10 °C and a cooling capacity estimated at 15 kW. The analysis of the system in case of solar radiation, presents a COP of 2.88, an improvement of 30.05 % compared to the conventional system, with an exergy efficiency of 25.6 %. In addition, the effect of several operating parameters on the system performance are discussed, including solar irradiation, mass flow fraction, ambient temperature and evaporation temperature. Simulation results show that the energy savings of the proposed system can reach a threshold value of 43 % for a mass flow fraction α = 0.9 or at a maximum solar irradiation of 1000 W/m 2 .

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management X
Published
2024-12-25
DOI
https://doi.org/10.1016/j.ecmx.2024.100854
Citations
5
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and exergo-energetic analysis of an energy-efficient solar-assisted transcritical CO2 refrigeration system with two-phase ejector

Fréderic Lontsi, Thomas Djiako, Orelien Boupda, Roger Yannick EKANI
5 citations
Energy Conversion and Management X
Refrigeration and Air Conditioning Technologies
1.06
article

Development and exergo-energetic analysis of an energy-efficient solar-assisted transcritical CO2 refrigeration system with two-phase ejector

Fréderic Lontsi, Thomas Djiako, Orelien Boupda, Roger Yannick EKANI
article en
5 citations

Abstract

• A new solar-assisted vapor compression/ejector refrigeration system using R744 as the working fluid was developed and analyzed. • The ejector performance and the energy and exergy analysis of the system were evaluated. • The COP and energy saving values of the system for a solar irradiation of 300W/m 2 are 2.88 and 30%, respectively. • The COP reaches a value of 3.4 for an evaporation temperature of 5 °C. • The PTC is the system component that destroys the most exergy, followed by the compressor, the ejector and the gas cooler. This paper proposes and evaluates the performance of a new refrigeration and energy production system that combines the vapor compression cycle with ejector and the Brayton subcycle using CO 2 as the working fluid. In this system, the Brayton cycle uses solar radiation as thermal energy, the heat of which is transmitted to the fluid through a solar concentrator, then expanded in a turbine to produce mechanical energy favorable to the reduction of energy consumed by the compressor of the refrigeration cycle. The study aims to examine the energy and exergy performance criteria of the combined system. The developed model of the system was simulated using EES software, for an evaporation temperature of −10 °C and a cooling capacity estimated at 15 kW. The analysis of the system in case of solar radiation, presents a COP of 2.88, an improvement of 30.05 % compared to the conventional system, with an exergy efficiency of 25.6 %. In addition, the effect of several operating parameters on the system performance are discussed, including solar irradiation, mass flow fraction, ambient temperature and evaporation temperature. Simulation results show that the energy savings of the proposed system can reach a threshold value of 43 % for a mass flow fraction α = 0.9 or at a maximum solar irradiation of 1000 W/m 2 .

Energy Conversion and Management XVol. 25
University of Douala (CM), Institut Universitaire du Golfe de Guinée (CM), University of Ngaoundéré (CM)
Affordable and clean energy
Openalex Percentile: Top 25%
Refrigeration and Air Conditioning Technologies
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.