Multiplex Trifluoromethyl and Hydroxyl Radical Chemistry Enables High-Resolution Protein Footprinting
Hydroxyl radical-based protein footprinting (HRPF) coupled with mass spectrometry is a valuable medium-resolution technique in structural biology, facilitating the assessment of protein structure and molecular-level interactions in solution conditions. In HRPF with X-rays (XFP), hydroxyl radicals generated by water radiolysis covalently label multiple amino acid (AA) side chains. However, HRPF technologies face challenges in achieving their full potential due to the broad (>10<sup>3</sup>) dynamic range of AA reactivity with <sup>•</sup>OH and difficulty in detecting slightly modified residues, most notably in peptides with highly reactive residues like methionine, or where all residues have low <sup>•</sup>OH reactivities. To overcome this limitation, we developed a multiplex labeling chemistry that utilizes both CF<sub>3</sub> radicals (<sup>•</sup>CF<sub>3</sub>) produced from a trifluoromethylation (TFM) reagent and OH radicals (<sup>•</sup>OH), under controlled and optimized radiolysis doses generated by X-rays. We optimized the dual <sup>•</sup>CF<sub>3</sub>/<sup>•</sup>OH chemistry using model peptides and proteins, thereby extending the existing <sup>•</sup>OH labeling platform to incorporate simultaneous <sup>•</sup>CF<sub>3</sub> labeling. We labeled >50% of the protein sequence and >80% of protein solvent-accessible AAs via multiplex TFM labeling resulting in high-resolution footprinting, primarily by enhancing the labeling of AAs with low <sup>•</sup>OH reactivity via the <sup>•</sup>CF<sub>3</sub> channel, while labeling moderate and highly <sup>•</sup>OH-reactive AAs in both <sup>•</sup>CF<sub>3</sub> and <sup>•</sup>OH channels. Moreover, the low reactivity of methionine with <sup>•</sup>CF<sub>3</sub> enabled the detection and quantification of additional AAs labeled by <sup>•</sup>CF<sub>3</sub> within methionine-containing peptides. Finally, we found that the solvent accessibility of protein AAs directly correlated with <sup>•</sup>CF<sub>3</sub> labeling, demonstrating that multiplex TFM labeling enables a high-resolution assessment of molecular interactions for enhanced HRPF.
Authors
- Nanak S. Dhillon (ORCID: https://orcid.org/0000-0002-4141-4483)
- Janna Kiselar (ORCID: https://orcid.org/0000-0002-6240-7522)
- Rohit Jain (ORCID: https://orcid.org/0000-0002-0780-1869)
- Mark R. Chance (ORCID: https://orcid.org/0000-0002-2991-6405)
- Erik R. Farquhar (ORCID: https://orcid.org/0000-0002-6419-038X)
- Nayeon Jeon (ORCID: https://orcid.org/0000-0002-4459-8716)
Institutions
- University School (US)
- Case Western Reserve University (US)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2024-12-25
- DOI
- https://doi.org/10.1021/acs.analchem.4c04610
- Citations
- 3
- Primary Topic
- Mass Spectrometry Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.72
Funders
- National Institute of General Medical Sciences
- Division of Biological Infrastructure
- Brookhaven National Laboratory