Comparison of the primary stability of orthodontic mini-screws manufactured by the Computer Numerically Control and Selective Laser Melting manufacturing methods: An exploratory study

Background: This study was to assess the primary stability of orthodontic mini-screws of the same design produced by a conventional and a novel manufacturing method. Methods: A total of 150 orthodontic mini-screws with a body length of 8 mm, a diameter of 1.6 mm, a button head, and a self-drilling feature were used in the study. Mini-screws were manufactured through computer numerically controlled (CNC) and selective laser melting (SLM) manufacturing methods. Titanium (T) and stainless steel (SS) alloys were used as manufacturing materials. The study was conducted on three groups; CNC-T, SLM-T and SLM-SS. Mini-screws were placed at 60- and 90-degree angles in fresh bovine femur bones, where the cortical bone thickness was 2 mm. With the radiofrequency analysis (RFA) technique, the stability of the mini-screws was determined immediately after they were placed (F0), immediately after applying orthodontic force to the mini-screw (F1), after six hours (F6), and after 24 hours (F24). Three-way robust ANOVA was used to compare the data, and the Bonferroni correction was statistically applied. Results: Except for the insertion angle of the mini-screw, the group and time factors had statistically significant effects on the RFA values. The highest RFA value was detected in the SLM-T group. Conclusion: Orthodontic mini-screws manufactured from titanium or stainless steel alloys using the SLM technology can be an alternative to mini-screws manufactured using the traditional manufacturing method. The mini-screws manufactured using the SLM technology demonstrated adequate primary stability when subjected to an orthodontic force. Keywords: Orthodontic mini-screw, Primary stability, Selective laser melting, Computer numerical control, Radiofrequency analysis

Authors

Institutions

Publication Details

Journal
Selcuk Dental Journal
Published
2024-12-23
DOI
https://doi.org/10.15311/selcukdentj.1497317
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the primary stability of orthodontic mini-screws manufactured by the Computer Numerically Control and Selective Laser Melting manufacturing methods: An exploratory study

Meriç Öztürk Yaşar, Celal Irgın
Selcuk Dental Journal
Additive Manufacturing Materials and Processes
article

Comparison of the primary stability of orthodontic mini-screws manufactured by the Computer Numerically Control and Selective Laser Melting manufacturing methods: An exploratory study

Meriç Öztürk Yaşar, Celal Irgın
article en

Abstract

Background: This study was to assess the primary stability of orthodontic mini-screws of the same design produced by a conventional and a novel manufacturing method. Methods: A total of 150 orthodontic mini-screws with a body length of 8 mm, a diameter of 1.6 mm, a button head, and a self-drilling feature were used in the study. Mini-screws were manufactured through computer numerically controlled (CNC) and selective laser melting (SLM) manufacturing methods. Titanium (T) and stainless steel (SS) alloys were used as manufacturing materials. The study was conducted on three groups; CNC-T, SLM-T and SLM-SS. Mini-screws were placed at 60- and 90-degree angles in fresh bovine femur bones, where the cortical bone thickness was 2 mm. With the radiofrequency analysis (RFA) technique, the stability of the mini-screws was determined immediately after they were placed (F0), immediately after applying orthodontic force to the mini-screw (F1), after six hours (F6), and after 24 hours (F24). Three-way robust ANOVA was used to compare the data, and the Bonferroni correction was statistically applied. Results: Except for the insertion angle of the mini-screw, the group and time factors had statistically significant effects on the RFA values. The highest RFA value was detected in the SLM-T group. Conclusion: Orthodontic mini-screws manufactured from titanium or stainless steel alloys using the SLM technology can be an alternative to mini-screws manufactured using the traditional manufacturing method. The mini-screws manufactured using the SLM technology demonstrated adequate primary stability when subjected to an orthodontic force. Keywords: Orthodontic mini-screw, Primary stability, Selective laser melting, Computer numerical control, Radiofrequency analysis

Selcuk Dental JournalVol. 11(3)
Yozgat Bozok Üniversitesi (TR), Erciyes University (TR)
Openalex Percentile: Top 75%
Additive Manufacturing Materials and Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of the primary stability of orthodontic mini-screws manufactured by the Computer Numerically Control and Selective Laser Melting manufacturing methods: An exploratory study — Meriç Öztürk Yaşar, Celal Irgın · Selcuk Dental Journal (2024) | TGRS Research Map | TGRS