Corrosion Resistance and Structure of Cr−O−N Coatings Formed in Vacuum Arc Plasma Fluxes With PIIID

ABSTRACT Cr−O−N‐based vacuum arc coatings are very promising for the wear and corrosion protection of various steel parts. The aim of the work was to determine the effect of frequency and amplitude of the pulsed bias voltage (U B ) on the elemental and phase composition, mechanical, and corrosion properties of Cr−O−N coatings. They have an amorphous structure with embedded nanosized solid solution crystallites based on CrN with a cubic structure and Cr 2 O 3 with a rhombohedral structure. The increase in the bias voltage results in a reduction in the grain size of the Cr 2 O 3 and CrN phases by about four times to about 5 nm, as well as a change in the CrN phase content in the coating. The lattice parameter increases slightly for the Cr 2 O 3 phase but decreases for the CrN phase. The increase in the pulse frequency results in an increase in the CrN phase content in the coating and the lattice constant of both phases and a slight decrease in the crystallite size. The hardness of Cr−O−N coatings slightly increased with the U B from 26 ± 1 GPa (DC) to 28 ± 1 GPa (−300 V, pulsed), and the elastic modulus ranges from 290 to 310 GPa. The greatest changes were observed in corrosion resistance. With an increase in the bias voltage and pulse frequency, the corrosion current of Cr−O−N coatings on steel in 3% NaCl solution decreased by three orders of magnitude compared to coatings deposited at DC voltage and by five orders of magnitude compared to the base steel. Therefore, the use of a pulsed bias voltage with a frequency of at least 10 kHz and an amplitude of 700 V can significantly increase the corrosion resistance of Cr−O−N coatings on steel substrates.

Authors

Institutions

Publication Details

Journal
Materials and Corrosion
Published
2024-12-23
DOI
https://doi.org/10.1002/maco.202414543
Citations
2
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Resistance and Structure of Cr−O−N Coatings Formed in Vacuum Arc Plasma Fluxes With PIIID

Mirosław Sawczak, Konrad Trzciński, Maria Gazda, H.Yu. Rostova et al.
2 citations
Materials and Corrosion
Metal and Thin Film Mechanics
0.54
article

Corrosion Resistance and Structure of Cr−O−N Coatings Formed in Vacuum Arc Plasma Fluxes With PIIID

Mirosław Sawczak, Konrad Trzciński, Maria Gazda, H.Yu. Rostova, Jacek Ryl, B. Warcholiński, A. Gilewicz, E.N. Reshetnyak, А.С. Куприн, І.О. Klimenko
article en
2 citations

Abstract

ABSTRACT Cr−O−N‐based vacuum arc coatings are very promising for the wear and corrosion protection of various steel parts. The aim of the work was to determine the effect of frequency and amplitude of the pulsed bias voltage (U B ) on the elemental and phase composition, mechanical, and corrosion properties of Cr−O−N coatings. They have an amorphous structure with embedded nanosized solid solution crystallites based on CrN with a cubic structure and Cr 2 O 3 with a rhombohedral structure. The increase in the bias voltage results in a reduction in the grain size of the Cr 2 O 3 and CrN phases by about four times to about 5 nm, as well as a change in the CrN phase content in the coating. The lattice parameter increases slightly for the Cr 2 O 3 phase but decreases for the CrN phase. The increase in the pulse frequency results in an increase in the CrN phase content in the coating and the lattice constant of both phases and a slight decrease in the crystallite size. The hardness of Cr−O−N coatings slightly increased with the U B from 26 ± 1 GPa (DC) to 28 ± 1 GPa (−300 V, pulsed), and the elastic modulus ranges from 290 to 310 GPa. The greatest changes were observed in corrosion resistance. With an increase in the bias voltage and pulse frequency, the corrosion current of Cr−O−N coatings on steel in 3% NaCl solution decreased by three orders of magnitude compared to coatings deposited at DC voltage and by five orders of magnitude compared to the base steel. Therefore, the use of a pulsed bias voltage with a frequency of at least 10 kHz and an amplitude of 700 V can significantly increase the corrosion resistance of Cr−O−N coatings on steel substrates.

Materials and CorrosionVol. 76(4)
Gdańsk University of Technology (PL), Koszalin University of Technology (PL), Kharkiv Institute of Physics and Technology (UA), Institute of Fluid Flow-Machinery (PL), Polish Academy of Sciences (PL)
Openalex Percentile: Top 37%
Metal and Thin Film Mechanics
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.