Finite Element Analyses of Three Minimally Invasive Fixation Techniques for Treating Sanders Type II Intra‑Articular Calcaneal Fractures

Category: Hindfoot; Trauma Introduction/Purpose: Calcaneal Sanders type II or III fractures are highly disabling with significant burden. Surgical treatment modalities include open reduction and internal fixation (ORIF) techniques and a variety of minimally invasive surgical (MIS) approaches. ORIF techniques are associated with complications and traditional MIS techniques need extensive intraoperative fluoroscopic procedures. The present study aims to investigate the effects of three different minimally invasive internal fixation (MIIF) techniques used to treat Sanders type II intra-articular calcaneal fractures using finite element analyses. Methods: A 64-row spiral computed tomography scan was used to observe the calcaneus of a healthy adult. The scanning data were imported into Mimics in a DICOM format. Using a new model of a Sanders type II-B intra-articular calcaneal fracture, three minimally invasive techniques were simulated. Technique A involved fixation using an isolated minimally invasive locking plate; Technique B used a minimally invasive locking plate with one medial support screw; and Technique C simulated a screw fixation technique using four 4.0-mm screws. After simulating a 640-N load on the subtalar facet, the maximum displacement and von Mises stress of fragments and implants were recorded to evaluate the biomechanical stability of different fixation techniques using finite element analyses. Results: After stress loading, the maximum displacements of the fragments and implants were located at the sustentaculum tali and the tip of sustentaculum tali screw, respectively, in the three techniques; however, among the three techniques, Technique B had better results for displacement of both. The maximum von Mises stress on the fragments was < 56 Mpa, and stress on the implants using the three techniques was less than the yield strength, with Technique C having the least stress. Conclusion: All three techniques were successful in providing a stable fixation for Sanders type II intra-articular calcaneal fractures, while the minimally invasive calcaneal locking plate with medial support screw fixation approach exhibited greater stability, leading to improved enhancement for the facet fragment; however, screw fixation dispersed the stress more effectively than the other two techniques.

Authors

Publication Details

Journal
Foot & Ankle Orthopaedics
Published
2024-10-01
DOI
https://doi.org/10.1177/2473011424s00289
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analyses of Three Minimally Invasive Fixation Techniques for Treating Sanders Type II Intra‑Articular Calcaneal Fractures

Zhongmin Shi, Wenqi Gu
Foot & Ankle Orthopaedics
Foot and Ankle Surgery
article

Finite Element Analyses of Three Minimally Invasive Fixation Techniques for Treating Sanders Type II Intra‑Articular Calcaneal Fractures

Zhongmin Shi, Wenqi Gu
article en

Abstract

Category: Hindfoot; Trauma Introduction/Purpose: Calcaneal Sanders type II or III fractures are highly disabling with significant burden. Surgical treatment modalities include open reduction and internal fixation (ORIF) techniques and a variety of minimally invasive surgical (MIS) approaches. ORIF techniques are associated with complications and traditional MIS techniques need extensive intraoperative fluoroscopic procedures. The present study aims to investigate the effects of three different minimally invasive internal fixation (MIIF) techniques used to treat Sanders type II intra-articular calcaneal fractures using finite element analyses. Methods: A 64-row spiral computed tomography scan was used to observe the calcaneus of a healthy adult. The scanning data were imported into Mimics in a DICOM format. Using a new model of a Sanders type II-B intra-articular calcaneal fracture, three minimally invasive techniques were simulated. Technique A involved fixation using an isolated minimally invasive locking plate; Technique B used a minimally invasive locking plate with one medial support screw; and Technique C simulated a screw fixation technique using four 4.0-mm screws. After simulating a 640-N load on the subtalar facet, the maximum displacement and von Mises stress of fragments and implants were recorded to evaluate the biomechanical stability of different fixation techniques using finite element analyses. Results: After stress loading, the maximum displacements of the fragments and implants were located at the sustentaculum tali and the tip of sustentaculum tali screw, respectively, in the three techniques; however, among the three techniques, Technique B had better results for displacement of both. The maximum von Mises stress on the fragments was < 56 Mpa, and stress on the implants using the three techniques was less than the yield strength, with Technique C having the least stress. Conclusion: All three techniques were successful in providing a stable fixation for Sanders type II intra-articular calcaneal fractures, while the minimally invasive calcaneal locking plate with medial support screw fixation approach exhibited greater stability, leading to improved enhancement for the facet fragment; however, screw fixation dispersed the stress more effectively than the other two techniques.

Foot & Ankle OrthopaedicsVol. 9(4)
Good health and well-being
Openalex Percentile: Top 68%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.