EVALUASI KINERJA HEAT EXCHANGER 260E-103 PADA KILANG LUBE OIL COMPLEX III UNIT 260 PT KILANG PERTAMINA INTERNASIONAL RU IV CILACAP

In the process of processing petroleum, PT Pertamina International RU IV Cilacap is equipped with a heat exchanger asa supporting tool for the production and processing. Heat exchanger functions as a heat exchange that works with theprinciple of heat exchange without mass transfer. The use of heat exchangers that are in extreme environments and areused for a long period of time to pass fluids, there is a high probability of deposit formation or impurities that can affectthe pressure drop and decrease the performance efficiency of the heat exchanger in terms of heat exchange. Planning forcleaning must be considered to maintain the performance of the heat exchanger performance so that it remains in optimalcondition. The heat exchanger that will be evaluated in this study is Heat Exchanger 260E-103 at PT PertaminaInternational RU IV Cilacap. The research was conducted using quantitative methods through the calculation of foulingfactor, pressure drop, and heat transfer efficiency. The results showed that the Rd value of Heat Exchanger 260E-103 ofLMO was 0.0317 hr ft2 oF/Btu; 0.0058 hr ft2 oF/Btu; 0.0048 hr ft2 oF/Btu, MMO was 0.0193 hr ft2 oF/Btu; 0.0157 hr ft2oF/Btu; 0.0070 hr ft2 oF/Btu, and DAO of 0.0153 hr ft2 oF/Btu; 0.0193 hr ft2 oF/Btu; 0.0029 hr ft2 oF/Btu. The pressuredrop value of Heat Exchanger 260E-103 of LMO is 12.021 Psi; 10.632 Psi; 10.416 Psi, MMO is 11.077 Psi; 11.108 Psi;10.435 Psi, and DAO is 14.149 Psi; 13.764 Psi; 13.625 Psi. The efficiency for Heat Exchanger 260E-103 of LMO is22.81%; 79.47%; 82.16%, MMO is 29.07%; 46.03%; 72.16%, and DAO is 17.43%; 60.06%; 45.04%. The results showthat Heat Exchanger 260E-103 is not suitable for use because it has Rd and pressure drop values exceeding normallimits, and efficiency is below standard.

Authors

Institutions

Publication Details

Journal
Journal of Sustainable Energy Development.
Published
2024-12-24
DOI
https://doi.org/10.19184/jsed.v2i2.1364
Primary Topic
Natural Products and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUASI KINERJA HEAT EXCHANGER 260E-103 PADA KILANG LUBE OIL COMPLEX III UNIT 260 PT KILANG PERTAMINA INTERNASIONAL RU IV CILACAP

Villia Rian Ashari, Welayaturromadhona Welayaturromadhona
3 links
Journal of Sustainable Energy Development.
Natural Products and Applications
article

EVALUASI KINERJA HEAT EXCHANGER 260E-103 PADA KILANG LUBE OIL COMPLEX III UNIT 260 PT KILANG PERTAMINA INTERNASIONAL RU IV CILACAP

Villia Rian Ashari, Welayaturromadhona Welayaturromadhona
article en

Abstract

In the process of processing petroleum, PT Pertamina International RU IV Cilacap is equipped with a heat exchanger asa supporting tool for the production and processing. Heat exchanger functions as a heat exchange that works with theprinciple of heat exchange without mass transfer. The use of heat exchangers that are in extreme environments and areused for a long period of time to pass fluids, there is a high probability of deposit formation or impurities that can affectthe pressure drop and decrease the performance efficiency of the heat exchanger in terms of heat exchange. Planning forcleaning must be considered to maintain the performance of the heat exchanger performance so that it remains in optimalcondition. The heat exchanger that will be evaluated in this study is Heat Exchanger 260E-103 at PT PertaminaInternational RU IV Cilacap. The research was conducted using quantitative methods through the calculation of foulingfactor, pressure drop, and heat transfer efficiency. The results showed that the Rd value of Heat Exchanger 260E-103 ofLMO was 0.0317 hr ft2 oF/Btu; 0.0058 hr ft2 oF/Btu; 0.0048 hr ft2 oF/Btu, MMO was 0.0193 hr ft2 oF/Btu; 0.0157 hr ft2oF/Btu; 0.0070 hr ft2 oF/Btu, and DAO of 0.0153 hr ft2 oF/Btu; 0.0193 hr ft2 oF/Btu; 0.0029 hr ft2 oF/Btu. The pressuredrop value of Heat Exchanger 260E-103 of LMO is 12.021 Psi; 10.632 Psi; 10.416 Psi, MMO is 11.077 Psi; 11.108 Psi;10.435 Psi, and DAO is 14.149 Psi; 13.764 Psi; 13.625 Psi. The efficiency for Heat Exchanger 260E-103 of LMO is22.81%; 79.47%; 82.16%, MMO is 29.07%; 46.03%; 72.16%, and DAO is 17.43%; 60.06%; 45.04%. The results showthat Heat Exchanger 260E-103 is not suitable for use because it has Rd and pressure drop values exceeding normallimits, and efficiency is below standard.

Journal of Sustainable Energy Development.Vol. 2(2)
Universitas Jember (ID)
Affordable and clean energy
Openalex Percentile: Top 57%
Natural Products and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EVALUASI KINERJA HEAT EXCHANGER 260E-103 PADA KILANG LUBE OIL COMPLEX III UNIT 260 PT KILANG PERTAMINA INTERNASIONAL RU IV CILACAP — Villia Rian Ashari, Welayaturromadhona Welayaturromadhona · Journal of Sustainable Energy Development. (2024) | TGRS Research Map | TGRS