Wearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement

This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.3390/ecsa-11-20500
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement

Jiří Přibil, Ivan Frollo, Anna Přibilová
Non-Invasive Vital Sign Monitoring
article

Wearable Reflectance PPG Optical Sensor Enabling Contact Pressure and Skin Temperature Measurement

Jiří Přibil, Ivan Frollo, Anna Přibilová
article en

Abstract

This paper describes the design, realization, and application of a wearable sensor based on the photoplethysmography (PPG) principle supplemented with a force-sensitive resistor and a thermometer for the measurement of contact pressure force and the temperature of the skin at the point where the optical part of the PPG sensor touches the finger. The performed experiments confirmed the essential influence of the applied contact force on the amplitude and ripple of the sensed PPG signal and the stability and precision of heart rate values determined from the PPG wave. Preliminary measurements showed that the response to the applied contact force was principally different for fingers of male and female tested persons, so different scaling and pressure levels were applied in the main experiments. Contrariwise, differences between left and right hands were not significant. The influence of skin temperature changes could be ignored for these measurements due to the short time duration of the PPG signal recording (approx. 1 min).

Slovak Academy of Sciences (SK), Institute of Measurement Science of the Slovak Academy of Sciences (SK)
Affordable and clean energy
Openalex Percentile: Top 77%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.