Formulation and Evaluation of Sulfoxy Amine Xanthan Gum Based Ocular Inserts.

The aim of the research work is use to modify xanthan gum in formulation and evaluation of ocular inserts. Method and materials: Ocular inserts was made from ciprofloxacine, modified xanthan gum, propylene glycol, glycerin by using solvent casting method. Result and Discussion: FTIR study a major characteristic peak of ciprofloxacin was found at 3540.67cm. The result of DSC was found at the ciprofloxacin compared two endothermic peaks at 154c and 168c.The thickness was found in between 0.12+-0.05 to 6.8+-0.05. The ocular inserts were coated with Eudragit S100.The ocular inserts using propylene glycol and modified xanthan gum as a polymer were successfully prepared and can be effectively conclusion based on these finding. It was concluded that the designed ocular inserts are a realistic alternative to conventional eye drop by virtue of its ability to improve patient’s compliance, bioavailability and improving patient compliance.  

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-12-12
DOI
https://doi.org/10.53555/ajbr.v27i4s.5397
Primary Topic
Polysaccharides Composition and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Formulation and Evaluation of Sulfoxy Amine Xanthan Gum Based Ocular Inserts.

Sukumar M. Lande
African Journal of Biomedical Research
Polysaccharides Composition and Applications
article

Formulation and Evaluation of Sulfoxy Amine Xanthan Gum Based Ocular Inserts.

Sukumar M. Lande
article en

Abstract

The aim of the research work is use to modify xanthan gum in formulation and evaluation of ocular inserts. Method and materials: Ocular inserts was made from ciprofloxacine, modified xanthan gum, propylene glycol, glycerin by using solvent casting method. Result and Discussion: FTIR study a major characteristic peak of ciprofloxacin was found at 3540.67cm. The result of DSC was found at the ciprofloxacin compared two endothermic peaks at 154c and 168c.The thickness was found in between 0.12+-0.05 to 6.8+-0.05. The ocular inserts were coated with Eudragit S100.The ocular inserts using propylene glycol and modified xanthan gum as a polymer were successfully prepared and can be effectively conclusion based on these finding. It was concluded that the designed ocular inserts are a realistic alternative to conventional eye drop by virtue of its ability to improve patient’s compliance, bioavailability and improving patient compliance.  

African Journal of Biomedical Research
Zero hunger
Openalex Percentile: Top 71%
Polysaccharides Composition and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.