The impact of air entraining on frost endurance in 3D-printed concrete: the function of printing orientation and curing process

This study evaluated the freeze-thaw (F&T) resistance of 3D-printed concrete by analyzing the effects of air-entraining agent (AEA) concentrations, curing methods, and core orientations. Concrete specimens (600 x 600 x 150 mm) with 0%, 0.1%, 0.15%, and 0.2% AEA were cured and tested after 28 days. Cores were drilled horizontally and vertically and then subjected to 360 F&T cycles according to ASTM C666/Procedure B. Microstructural analyses (BET, MIP, SEM, XRD) evaluated changes in pore structure. Results showed 25% of the samples endured 300 cycles without significant damage. F&T damage occurred primarily at interlayer bonds. Horizontal cores showed greater durability due to reduced interlayer gaps. AEA at 0.1% significantly improved F&T resistance and increased dynamic modulus by 15%. BET and MIP analyses showed a 20% increase in average pore size, while SEM confirmed air voids. Optimized AEA levels and curing methods improved the durability of 3D-printed concrete in frost-prone conditions.

Authors

Institutions

Publication Details

Journal
Journal of Sustainable Cement-Based Materials
Published
2024-12-24
DOI
https://doi.org/10.1080/21650373.2024.2443048
Citations
2
Primary Topic
Innovations in Concrete and Construction Materials
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of air entraining on frost endurance in 3D-printed concrete: the function of printing orientation and curing process

Yeşim Tarhan, Remzi Şahin
2 citations
Journal of Sustainable Cement-Based Materials
Innovations in Concrete and Construction Materials
0.53
article

The impact of air entraining on frost endurance in 3D-printed concrete: the function of printing orientation and curing process

Yeşim Tarhan, Remzi Şahin
article en
2 citations

Abstract

This study evaluated the freeze-thaw (F&T) resistance of 3D-printed concrete by analyzing the effects of air-entraining agent (AEA) concentrations, curing methods, and core orientations. Concrete specimens (600 x 600 x 150 mm) with 0%, 0.1%, 0.15%, and 0.2% AEA were cured and tested after 28 days. Cores were drilled horizontally and vertically and then subjected to 360 F&T cycles according to ASTM C666/Procedure B. Microstructural analyses (BET, MIP, SEM, XRD) evaluated changes in pore structure. Results showed 25% of the samples endured 300 cycles without significant damage. F&T damage occurred primarily at interlayer bonds. Horizontal cores showed greater durability due to reduced interlayer gaps. AEA at 0.1% significantly improved F&T resistance and increased dynamic modulus by 15%. BET and MIP analyses showed a 20% increase in average pore size, while SEM confirmed air voids. Optimized AEA levels and curing methods improved the durability of 3D-printed concrete in frost-prone conditions.

Journal of Sustainable Cement-Based MaterialsVol. 14(3)
Ardahan University (TR), Technical and Vocational University (IR), Atatürk University (TR)
Climate action
Openalex Percentile: Top 32%
Innovations in Concrete and Construction Materials
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.