MScope: A Reliable Battery for Functional Status Assessment in Multiple Sclerosis

Multiple sclerosis (MS) is a neurodegenerative disease that often leads to severe disability. Although exercise, particularly strength training, improves health outcomes in MS, no standardized, reliable tool exists for functional assessment to inform tailored exercise prescriptions and patients’ categorization. This study aimed to validate the reliability of the MScope battery, a comprehensive tool incorporating structural, functional, and neuromuscular assessments to objectively evaluate patients with MS. A reproducibility study was conducted with 40 MS patients who completed the MScope battery twice, 72 h apart. Tests included structural (muscle thickness of the vastus lateralis and rectus femoris), functional (sit-to-stand, timed up-and-go, 10 m and six-minute walking test), and neuromuscular tests (isometric strength during the squat and leg extension exercises and handgrip strength). Intraclass correlation coefficients (ICCs), Bland–Altman plots, and the coefficient of variation (CV) were used to evaluate intra- and inter-day reliability. The MScope battery showed high intra- and inter-day reliability, with ICC values ranging from 0.79 to 0.99. Muscle thickness measurements, along with handgrip strength, demonstrated excellent reliability (ICC > 0.9, CV < 5%). Functional tests, including the timed up-and-go, 10 m walk, and sit-to-stand variations, maintained consistent scores (ICC > 0.85, CV < 10%). The six-minute walking test exhibited excellent inter-day reliability (ICC = 0.94, CV < 4%). Neuromuscular assessments showed strong reliability with minor day-to-day variability (ICC = 0.75–0.95, CV < 8%). The battery’s overall consistency supports its use as a reliable tool for assessing functional status in MS patients.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-12-24
DOI
https://doi.org/10.3390/app15010011
Primary Topic
Multiple Sclerosis Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MScope: A Reliable Battery for Functional Status Assessment in Multiple Sclerosis

Susana López‐Ortiz, José Pinto-Fraga, Alba Chavarría‐Miranda, Celia García‐Chico et al.
Applied Sciences
Multiple Sclerosis Research Studies
article

MScope: A Reliable Battery for Functional Status Assessment in Multiple Sclerosis

Susana López‐Ortiz, José Pinto-Fraga, Alba Chavarría‐Miranda, Celia García‐Chico, Sergio Maroto‐Izquierdo, Nieves Téllez, Daniel Lisardo, Irati Jauregui-Fajardo
article en

Abstract

Multiple sclerosis (MS) is a neurodegenerative disease that often leads to severe disability. Although exercise, particularly strength training, improves health outcomes in MS, no standardized, reliable tool exists for functional assessment to inform tailored exercise prescriptions and patients’ categorization. This study aimed to validate the reliability of the MScope battery, a comprehensive tool incorporating structural, functional, and neuromuscular assessments to objectively evaluate patients with MS. A reproducibility study was conducted with 40 MS patients who completed the MScope battery twice, 72 h apart. Tests included structural (muscle thickness of the vastus lateralis and rectus femoris), functional (sit-to-stand, timed up-and-go, 10 m and six-minute walking test), and neuromuscular tests (isometric strength during the squat and leg extension exercises and handgrip strength). Intraclass correlation coefficients (ICCs), Bland–Altman plots, and the coefficient of variation (CV) were used to evaluate intra- and inter-day reliability. The MScope battery showed high intra- and inter-day reliability, with ICC values ranging from 0.79 to 0.99. Muscle thickness measurements, along with handgrip strength, demonstrated excellent reliability (ICC > 0.9, CV < 5%). Functional tests, including the timed up-and-go, 10 m walk, and sit-to-stand variations, maintained consistent scores (ICC > 0.85, CV < 10%). The six-minute walking test exhibited excellent inter-day reliability (ICC = 0.94, CV < 4%). Neuromuscular assessments showed strong reliability with minor day-to-day variability (ICC = 0.75–0.95, CV < 8%). The battery’s overall consistency supports its use as a reliable tool for assessing functional status in MS patients.

Applied SciencesVol. 15(1)
Universidad Europea Miguel de Cervantes (ES), Hospital Clínico Universitario de Valladolid (ES)
Good health and well-being
Openalex Percentile: Top 61%
Multiple Sclerosis Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.