Numerical Study of Thermal and Resistance Characteristics in the Vortex-Enhanced Tube

Heat transfer enhancement is always pursued in the industry to achieve high-performance and low-energy-consumption heat exchange devices and systems. For decades, various types of heat transfer-enhancing tubes with differing geometries and wall configurations have been developed. In this paper, the heat transfer and pressure drop characteristics of air inside an innovative heat transfer tube with regular wall dimples, namely a vortex-enhanced tube, which has a great application prospect in the gas–gas heat exchanger, are numerically studied with an experimentally validated model. The effects of the depth, axial pitch, and radial rotation angle of the dimple in the tube wall on the convective heat transfer coefficient and friction drag coefficient are comprehensively analyzed. Based on the Performance Evaluation Criteria (PEC) of the tubes, the optimal parameters of the vortex-enhanced tube are obtained. When Re ranges from 10,000 to 40,000, the comprehensive evaluation factor of the vortex-enhanced tube is 1.29 times higher than the smooth tube. Dimple pacing, dimple depth, and dimple helical angle of the optimal tube type are 8 mm, 6 mm, and 83°, respectively.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-12-24
DOI
https://doi.org/10.3390/en18010013
Citations
1
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Study of Thermal and Resistance Characteristics in the Vortex-Enhanced Tube

Longjian Li, Xuefeng Jiang, Wenzhi Cui, Juanfang Liu et al.
1 citations
Energies
Heat Transfer Mechanisms
0.21
article

Numerical Study of Thermal and Resistance Characteristics in the Vortex-Enhanced Tube

Longjian Li, Xuefeng Jiang, Wenzhi Cui, Juanfang Liu, Yiang Li
article en
1 citations

Abstract

Heat transfer enhancement is always pursued in the industry to achieve high-performance and low-energy-consumption heat exchange devices and systems. For decades, various types of heat transfer-enhancing tubes with differing geometries and wall configurations have been developed. In this paper, the heat transfer and pressure drop characteristics of air inside an innovative heat transfer tube with regular wall dimples, namely a vortex-enhanced tube, which has a great application prospect in the gas–gas heat exchanger, are numerically studied with an experimentally validated model. The effects of the depth, axial pitch, and radial rotation angle of the dimple in the tube wall on the convective heat transfer coefficient and friction drag coefficient are comprehensively analyzed. Based on the Performance Evaluation Criteria (PEC) of the tubes, the optimal parameters of the vortex-enhanced tube are obtained. When Re ranges from 10,000 to 40,000, the comprehensive evaluation factor of the vortex-enhanced tube is 1.29 times higher than the smooth tube. Dimple pacing, dimple depth, and dimple helical angle of the optimal tube type are 8 mm, 6 mm, and 83°, respectively.

EnergiesVol. 18(1)
Chongqing University (CN), Sinochem Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 48%
Heat Transfer Mechanisms
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.