DC allowable electric field strength for naphthenic‐based and paraffin‐based transformer oils

Abstract Currently, the design of transformers insulation predominantly depends on the allowable alternating current (AC) field values for insulating oil established by Weidmann in the 1980s, lacking the research under direct current (DC) voltage for converter transformers. This study selects naphthenic oils and paraffin‐based oil transformer oil as research subjects, establishing a practical measurement platform to ascertain the oil breakdown characteristics under DC voltage. Furthermore, it statistically analyses the allowable DC field values of the oil. The findings elucidate that (1) the three‐parameter Weibull distribution is more suitable to conduct a statistical analysis for oil breakdown probability, yielding a fitting degree up to 99.95%. (2) For a constant electrode spacing, a 14.81% voltage increment escalates the breakdown probability of the oil gap from 3.33% to 73.33%. Concurrently, an increase in electrode spacing leads to a substantial decrement in the breakdown field strength of transformer oil, with KI25X experiencing a 54.51% reduction as electrode spacing extends from 5 to 25 mm. (3) The constant terms of the allowable DC field strength for S4, KI50X, and KI25X are found to be 19.728, 17.221, and 19.281, respectively. (4) A thorough analysis for differences in physicochemical properties and electrical parameters elucidates the variations in insulation properties across different transformer oils. The findings presented in this study offer essential theoretical and technical foundations for the design, evaluation, and enhancement of insulation structures in converter transformers.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2024-12-24
DOI
https://doi.org/10.1049/hve2.12506
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC allowable electric field strength for naphthenic‐based and paraffin‐based transformer oils

Bo Qi, Binhao Chen, Chengrong Li, Juzhen Wu et al.
High Voltage
Power Transformer Diagnostics and Insulation
article

DC allowable electric field strength for naphthenic‐based and paraffin‐based transformer oils

Bo Qi, Binhao Chen, Chengrong Li, Juzhen Wu, Chunjia Gao
article en

Abstract

Abstract Currently, the design of transformers insulation predominantly depends on the allowable alternating current (AC) field values for insulating oil established by Weidmann in the 1980s, lacking the research under direct current (DC) voltage for converter transformers. This study selects naphthenic oils and paraffin‐based oil transformer oil as research subjects, establishing a practical measurement platform to ascertain the oil breakdown characteristics under DC voltage. Furthermore, it statistically analyses the allowable DC field values of the oil. The findings elucidate that (1) the three‐parameter Weibull distribution is more suitable to conduct a statistical analysis for oil breakdown probability, yielding a fitting degree up to 99.95%. (2) For a constant electrode spacing, a 14.81% voltage increment escalates the breakdown probability of the oil gap from 3.33% to 73.33%. Concurrently, an increase in electrode spacing leads to a substantial decrement in the breakdown field strength of transformer oil, with KI25X experiencing a 54.51% reduction as electrode spacing extends from 5 to 25 mm. (3) The constant terms of the allowable DC field strength for S4, KI50X, and KI25X are found to be 19.728, 17.221, and 19.281, respectively. (4) A thorough analysis for differences in physicochemical properties and electrical parameters elucidates the variations in insulation properties across different transformer oils. The findings presented in this study offer essential theoretical and technical foundations for the design, evaluation, and enhancement of insulation structures in converter transformers.

High VoltageVol. 10(3)
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation
Openalex Percentile: Top 78%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.