A Prototype Gamma Imaging System for Measuring High-Intensity Proton Beam Spots Based on Pixelated CdZnTe Detectors

Measuring the high-power proton beam distribution on the target is critical for the stable operation of a spallation neutron source or an accelerator-driven subcritical system (ADS). This work preliminarily implemented a step of a proposed methodology for indirectly measuring the proton beam spot using pinhole imaging by detecting back-streaming secondary gammas. A prototype gamma imaging system based on pixelated cadmium zinc telluride (CdZnTe) detectors was developed to serve as a foundation for implementing the proposed method. Each detector consists of an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$11\times 11$ </tex-math></inline-formula> pixel array, with a pixel pitch of 1.72 mm. Readout electronic modules for two detectors were designed and realized. The energy and timing information of anode channels is obtained by analog application-specific integrated circuits (ASICs) called JCF032EB based on charge-sensitive amplifiers (CSAs), while the cathode channel signals are read out using CSAs and analog-to-digital converters (ADCs). The anode channels have a maximum input charge of up to 49 fC, while the equivalent noise charge (ENC) of most channels is less than 0.1 fC. Energy correction methods based on depth sensing using the cathode-to-anode (C/A) ratio and election drift time were applied. According to test results using radioactive sources, more than half of the anode channels achieve an energy resolution [full-width at half-maximum (FWHM)] better than 1.8% at 662 keV after depth correction, with the best channel reaching better than 1.1%. The imaging results of a 137Cs point source verified the functioning of the gamma imaging system. To verify the practical feasibility of the imaging method, a nickel target was activated on the proton beam line of the Associated Proton beam Experiment Platform (APEP) at the China Spallation Neutron Source (CSNS) and then imaged by the prototype system, which produced the expected results.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-12-24
DOI
https://doi.org/10.1109/tns.2024.3521654
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Prototype Gamma Imaging System for Measuring High-Intensity Proton Beam Spots Based on Pixelated CdZnTe Detectors

Hantao Jing, C. Q. Feng, Binbin Tian, Shubin Liu et al.
IEEE Transactions on Nuclear Science
Advanced Semiconductor Detectors and Materials
article

A Prototype Gamma Imaging System for Measuring High-Intensity Proton Beam Spots Based on Pixelated CdZnTe Detectors

Hantao Jing, C. Q. Feng, Binbin Tian, Shubin Liu, Ziheng Zhou, Y. Qin
article en

Abstract

Measuring the high-power proton beam distribution on the target is critical for the stable operation of a spallation neutron source or an accelerator-driven subcritical system (ADS). This work preliminarily implemented a step of a proposed methodology for indirectly measuring the proton beam spot using pinhole imaging by detecting back-streaming secondary gammas. A prototype gamma imaging system based on pixelated cadmium zinc telluride (CdZnTe) detectors was developed to serve as a foundation for implementing the proposed method. Each detector consists of an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$11\times 11$ </tex-math></inline-formula> pixel array, with a pixel pitch of 1.72 mm. Readout electronic modules for two detectors were designed and realized. The energy and timing information of anode channels is obtained by analog application-specific integrated circuits (ASICs) called JCF032EB based on charge-sensitive amplifiers (CSAs), while the cathode channel signals are read out using CSAs and analog-to-digital converters (ADCs). The anode channels have a maximum input charge of up to 49 fC, while the equivalent noise charge (ENC) of most channels is less than 0.1 fC. Energy correction methods based on depth sensing using the cathode-to-anode (C/A) ratio and election drift time were applied. According to test results using radioactive sources, more than half of the anode channels achieve an energy resolution [full-width at half-maximum (FWHM)] better than 1.8% at 662 keV after depth correction, with the best channel reaching better than 1.1%. The imaging results of a 137Cs point source verified the functioning of the gamma imaging system. To verify the practical feasibility of the imaging method, a nickel target was activated on the proton beam line of the Associated Proton beam Experiment Platform (APEP) at the China Spallation Neutron Source (CSNS) and then imaged by the prototype system, which produced the expected results.

IEEE Transactions on Nuclear ScienceVol. 72(3)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), China Spallation Neutron Source (CN), Institute of High Energy Physics (CN)
Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 78%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.