A Metrological Approach to the Performance Characterization of Eye- and Head-Tracking Interfaces in eXtended Reality
Given the increasing adoption of eXtended Reality Head-Mounted Displays (XR HMDs) and the related demand for hands-free Human-Machine Interaction (HMI), this paper introduces a metrological approach to the performance charac-terization of Eye- and Head-tracking input interfaces within XR scenarios. In particular, two metrics of interest are identified: Accuracy in selecting objects and Euclidean Distance between the detected gaze and reference points. Without loss of generality, the Microsoft HoloLens 2 HMD was considered as a case study. An experimental campaign involving eight subjects was conducted to investigate the intra- and inter-individual variability of the metrics considered. The obtained experimental results showed robust performance within the interfaces of HoloLens 2, thus allowing the development of high-information-rate XR applications in scenarios where precision tasks are needed.
Authors
- Mauro D’Arco (ORCID: https://orcid.org/0000-0003-1641-8359)
- Luigi Duraccio (ORCID: https://orcid.org/0000-0002-1356-5559)
- Annarita Tedesco (ORCID: https://orcid.org/0000-0001-7242-701X)
- Egidio De Benedetto (ORCID: https://orcid.org/0000-0002-2792-2131)
- Leopoldo Angrisani (ORCID: https://orcid.org/0000-0001-6932-6891)
- Pasquale Arpaïa (ORCID: https://orcid.org/0000-0002-5192-5922)
- Fabrizio Lo Regio (ORCID: https://orcid.org/0009-0003-9307-8340)
Institutions
- University of Naples Federico II (IT)
Publication Details
- Published
- 2024-10-21
- DOI
- https://doi.org/10.1109/metroxraine62247.2024.10795982
- Primary Topic
- Augmented Reality Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00