Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(AG):6Li and Silicon Photomultipliers

A linear position-sensitive neutron detector based on two silicon photomultiplier and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from SensL with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates were analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from SensL, there was no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector was about 10 mm, and without the diffusion reflector it was approximately 5 mm.

Authors

Institutions

Publication Details

Journal
Поверхность Рентгеновские синхротронные и нейтронные исследования
Published
2024-12-25
DOI
https://doi.org/10.31857/s1028096024080012
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(AG):6Li and Silicon Photomultipliers

Е. В. Алтынбаев, В. Н. Марин, Т. И. Глушкова, D. N. Trunov et al.
Поверхность Рентгеновские синхротронные и нейтронные исследования
Radiation Detection and Scintillator Technologies
article

Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(AG):6Li and Silicon Photomultipliers

Е. В. Алтынбаев, В. Н. Марин, Т. И. Глушкова, D. N. Trunov, Р. А. Садыков
article en

Abstract

A linear position-sensitive neutron detector based on two silicon photomultiplier and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from SensL with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates were analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from SensL, there was no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector was about 10 mm, and without the diffusion reflector it was approximately 5 mm.

Поверхность Рентгеновские синхротронные и нейтронные исследования(8)
Kurchatov Institute (RU), Institute for Nuclear Research (RU)
Affordable and clean energy
Openalex Percentile: Top 66%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.