Accuracy of Arterial Blood Gas: Quality Improvement Study

Background: Arterial blood gas (ABG) is indicated in almost all presenting problems in the emergency department (ED). When the clinical diagnosis does not match the ABG diagnosis, particularly in multiorgan failure, physicians level it as inaccurate. With the passage of time the role of ABG has been narrowed to the ICU as a monitor in ventilated patients. The accuracy of ABG can be tested by knowing and comparing the values of Hb% measured though ABG and CBC and by oxygen saturation measured though ABG and pulse oximetry. Method: This was a prospective observational cohort quality improvement study and ABG vs. CBC hemoglobin and ABG vs. pulse-oximeter oxygen saturation in over 74 adult patients admitted to the ED were evaluated in a tertiary care center. Arterial blood was collected properly and ABG-Hb/ABG-SO2 was measured at point-of-care testing with an ABG machine. Venous samples were collected at the same time and properly transported to the laboratory for CBC measurement. SpO2 was measured at bedside through pulse oximeter. Data were entered into a specifically designed database and analyzed statistically. Result: There was a strong positive correlation between ABG-Hb and CBC-Hb (p<0.001). The correlation between ABG-SO2 and pulse-oxi-SpO2 was also significant (p<0.001). Conclusion: Both the ABG-Hb vs. CBC-Hb and ABG-SO2 vs. pulse-oxi-SpO2 methods can be used as tools for testing accuracy and improving the quality of ABG. Confident use of ABG in the management of severely ill patients significantly improves outcomes [3]. Keyword: ABG (arterial blood gas); ED (emergency department); CBC (complete blood count); Pulse-Oxi (pulse oximeter); PI (perfusion index).

Authors

Institutions

Publication Details

Journal
International Journal of Medical and Biomedical Studies
Published
2024-12-24
DOI
https://doi.org/10.32553/ijmbs.v8i6.2914
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Arterial Blood Gas: Quality Improvement Study

Ravindra Kumar Das
International Journal of Medical and Biomedical Studies
Renal function and acid-base balance
article

Accuracy of Arterial Blood Gas: Quality Improvement Study

Ravindra Kumar Das
article en

Abstract

Background: Arterial blood gas (ABG) is indicated in almost all presenting problems in the emergency department (ED). When the clinical diagnosis does not match the ABG diagnosis, particularly in multiorgan failure, physicians level it as inaccurate. With the passage of time the role of ABG has been narrowed to the ICU as a monitor in ventilated patients. The accuracy of ABG can be tested by knowing and comparing the values of Hb% measured though ABG and CBC and by oxygen saturation measured though ABG and pulse oximetry. Method: This was a prospective observational cohort quality improvement study and ABG vs. CBC hemoglobin and ABG vs. pulse-oximeter oxygen saturation in over 74 adult patients admitted to the ED were evaluated in a tertiary care center. Arterial blood was collected properly and ABG-Hb/ABG-SO2 was measured at point-of-care testing with an ABG machine. Venous samples were collected at the same time and properly transported to the laboratory for CBC measurement. SpO2 was measured at bedside through pulse oximeter. Data were entered into a specifically designed database and analyzed statistically. Result: There was a strong positive correlation between ABG-Hb and CBC-Hb (p<0.001). The correlation between ABG-SO2 and pulse-oxi-SpO2 was also significant (p<0.001). Conclusion: Both the ABG-Hb vs. CBC-Hb and ABG-SO2 vs. pulse-oxi-SpO2 methods can be used as tools for testing accuracy and improving the quality of ABG. Confident use of ABG in the management of severely ill patients significantly improves outcomes [3]. Keyword: ABG (arterial blood gas); ED (emergency department); CBC (complete blood count); Pulse-Oxi (pulse oximeter); PI (perfusion index).

International Journal of Medical and Biomedical StudiesVol. 8(6)
Darbhanga Medical College and Hospital (IN)
Openalex Percentile: Top 67%
Renal function and acid-base balance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.