Performance evaluation of a Coriolis flowmeter for measuring mass flow rate of CO2 with impurities under CCS conditions

Accurate mass flowrate measurement of CO 2 with impurities in CCS transportation pipelines is challenging. The presence of impurities affects the phase behavior and physical properties of CO 2 -rich mixtures. This increases the difficulty in flow metering for financial accounting and custody transfer. In this paper, the performance of a Coriolis flowmeter for measuring the mass flowrate of CO 2 with impurities is evaluated. Experiments were conducted on a 50 mm bore horizontal pipeline on a purpose-built gas-liquid two-phase flow test rig for fluid temperature of 10∼18 °C and pressure of 50∼70 bar. The mass flowrate of liquid CO 2 is between 1000 kg/h and 3000 kg/h, and the gas volume fraction of the impurity gas is up to 15 %. Pure N 2 was injected into the test section as an impurity gas. An MLP model is established to reduce the errors in CO 2 mass flowrate measurement with impurities.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-24
DOI
https://doi.org/10.1016/j.measen.2024.101558
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of a Coriolis flowmeter for measuring mass flow rate of CO2 with impurities under CCS conditions

Yong Yan, Yichen Zhang, Haoyang Li, Wenbiao Zhang et al.
Measurement Sensors
Flow Measurement and Analysis
article

Performance evaluation of a Coriolis flowmeter for measuring mass flow rate of CO2 with impurities under CCS conditions

Yong Yan, Yichen Zhang, Haoyang Li, Wenbiao Zhang, Qin Wang
article en

Abstract

Accurate mass flowrate measurement of CO 2 with impurities in CCS transportation pipelines is challenging. The presence of impurities affects the phase behavior and physical properties of CO 2 -rich mixtures. This increases the difficulty in flow metering for financial accounting and custody transfer. In this paper, the performance of a Coriolis flowmeter for measuring the mass flowrate of CO 2 with impurities is evaluated. Experiments were conducted on a 50 mm bore horizontal pipeline on a purpose-built gas-liquid two-phase flow test rig for fluid temperature of 10∼18 °C and pressure of 50∼70 bar. The mass flowrate of liquid CO 2 is between 1000 kg/h and 3000 kg/h, and the gas volume fraction of the impurity gas is up to 15 %. Pure N 2 was injected into the test section as an impurity gas. An MLP model is established to reduce the errors in CO 2 mass flowrate measurement with impurities.

Measurement SensorsVol. 38
Zhejiang International Studies University (CN), North China Electric Power University (CN), Beihang University (CN)
Openalex Percentile: Top 73%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.