Further investigation on the measuring performance of a combination method of a volumetric positive-displacement flowmeter and a densitometer in measuring liquid fuel mass flow at low flow rates
This study evaluates the performance of a newly developed mass flowmeter which combines a positive-displacement (PD) type of volumetric flowmeter and a densitometer by focusing on the performance of the densitometer. The error in estimating the actual liquid density flowing through the volumetric flowmeter can be attributed to two factors: (i) measurement accuracy of the densitometer itself ranging between −0.12 % and −0.17 %. (ii) temperature variation existing between the combined two sensors estimated to be 0.5 °C by maximum, contributing to a density error of about 0.05 % for liquid fuel.
Authors
- Ryouji DOIHARA (ORCID: https://orcid.org/0000-0002-4191-0356)
- Shouta Kamazawa
- Nobuko Hosobuchi
- Kar-Hooi CHEONG (ORCID: https://orcid.org/0000-0003-2155-6123)
- Noriyuki Furuichi (ORCID: https://orcid.org/0000-0002-4845-9051)
- Shigenori Kasai
Institutions
- Hosei University (JP)
- National Institute of Advanced Industrial Science and Technology (JP)
Publication Details
- Journal
- Measurement Sensors
- Published
- 2024-12-24
- DOI
- https://doi.org/10.1016/j.measen.2024.101542
- Primary Topic
- Flow Measurement and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00