Full-automatic calibration device for test joints of hydraulic impulse tools

To ensure the optimal performance of hydraulic impulse tools, it is essential to test them on test joints with a controllable torque rate. These test joints must exhibit consistent friction rates, linearity, repeatability, and reproducibility. This article presents the design of a fully automated calibration device for hydraulic pulse tool test joints, detailing its structural principles and automatic control procedures. The calibration device enhances the efficiency of calibrating hydraulic impulse tool test joints, minimises errors from manual operations, and accommodates test joints of varying specifications. Experimental results demonstrate that the device achieves an indication error and repeatability better than 0.3 %, enabling precise calibration of the test joints' measurement characteristics.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-24
DOI
https://doi.org/10.1016/j.measen.2024.101374
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Full-automatic calibration device for test joints of hydraulic impulse tools

Zhong Tao, Xiang Ren, Zhenyu Wang
Measurement Sensors
Engineering Technology and Methodologies
article

Full-automatic calibration device for test joints of hydraulic impulse tools

Zhong Tao, Xiang Ren, Zhenyu Wang
article en

Abstract

To ensure the optimal performance of hydraulic impulse tools, it is essential to test them on test joints with a controllable torque rate. These test joints must exhibit consistent friction rates, linearity, repeatability, and reproducibility. This article presents the design of a fully automated calibration device for hydraulic pulse tool test joints, detailing its structural principles and automatic control procedures. The calibration device enhances the efficiency of calibrating hydraulic impulse tool test joints, minimises errors from manual operations, and accommodates test joints of varying specifications. Experimental results demonstrate that the device achieves an indication error and repeatability better than 0.3 %, enabling precise calibration of the test joints' measurement characteristics.

Measurement SensorsVol. 38
Shandong Institute of Metrology (CN), Kunshan Govisionox Optoelectronic (China) (CN), Duke Kunshan University (CN)
Affordable and clean energy
Openalex Percentile: Top 65%
Engineering Technology and Methodologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.