Comparison of external calibration and isotope dilution methods for iodine determination in foods by inductively coupled plasma mass spectrometry

This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.01 and 0.02 mg/kg, respectively). However, both methods showed good accuracy and precision for all SRM and the 26 food samples. Test results from both methods had a strong correlation (R<sup>2</sup> > 0.998) and no significant difference between the determination methods, even within test sample sectors based on the distribution in the AOAC food triangle (<i>p</i> > 0.970). <sup>129</sup>I spiked into the sample before or during alkaline extraction showed no significant difference in the test results (<i>p</i> = 0.989).

Authors

Institutions

Publication Details

Journal
Food Chemistry X
Published
2024-12-24
DOI
https://doi.org/10.1016/j.fochx.2024.102119
Citations
4
Primary Topic
Thyroid Disorders and Treatments
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of external calibration and isotope dilution methods for iodine determination in foods by inductively coupled plasma mass spectrometry

Christophe Zeder, Premmin Srisakda, Juntima Photi, Kunchit Judprasong et al.
4 citations
Food Chemistry X
Thyroid Disorders and Treatments
1.43
article

Comparison of external calibration and isotope dilution methods for iodine determination in foods by inductively coupled plasma mass spectrometry

Christophe Zeder, Premmin Srisakda, Juntima Photi, Kunchit Judprasong, Tiyanun Jurkvon
article en
4 citations

Abstract

This study sought to validate the external calibration curve (CAL) method for iodine analysis in 26 selected foods and then to compare the test result with the isotope dilution mass spectrometry (IDMS). Iodine was extracted by tetramethylammonium hydroxide (TMAH) and determined by ICP-MS using CAL and IDMS methods. The results showed that iodine determination using the IDMS method had higher precision than the CAL method (LOD of the method were 0.01 and 0.02 mg/kg, respectively). However, both methods showed good accuracy and precision for all SRM and the 26 food samples. Test results from both methods had a strong correlation (R<sup>2</sup> > 0.998) and no significant difference between the determination methods, even within test sample sectors based on the distribution in the AOAC food triangle (<i>p</i> > 0.970). <sup>129</sup>I spiked into the sample before or during alkaline extraction showed no significant difference in the test results (<i>p</i> = 0.989).

Food Chemistry XVol. 25
Mahidol University (TH), ETH Zurich (CH)
Eidgenössische Technische Hochschule Zürich, Mahidol University
Zero hunger
Openalex Percentile: Top 15%
Thyroid Disorders and Treatments
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.