Objective: Hypoattenuated leaflet thickening (HALT) is a computed tomography (CT) finding after transcatheter aortic valve replacement (TAVR) that is indicative of bioprosthetic valvular thrombosis. There are currently no standardized or validated methods for predicting HALT, which can cause bioprosthetic valve dysfunction and has been associated with adverse patient outcomes. The objective was to develop a novel fast-response, artificial intelligence, and machine learning (ML)-driven computational pipeline to predict HALT using preprocedural CT scans. Methods: The pipeline consisted of (1) pre-TAVR CT reconstruction and reduced order modeling simulations to automatically predict postprocedural geometric parameters, (2) a landmark-guided automated left ventricle segmentation method to predict hemodynamic parameters, and (3) statistical and ML analyses to develop HALT predictive metrics. Results: Pre- and postprocedural scans from 45 patients (21 with HALT, 24 without) were used as inputs for the pipeline. We identified statistically significant relationships between HALT and peak systolic blood velocity (P < .01) and peak systolic blood flow through the bioprosthetic valve (P < .01), left ventricular ejection time (P < .01), ejection volume (P < .05), and right coronary height (P < .05). ML-yielded metrics related to circulation in the neosinuses correlated strongly with HALT occurrence (P < .001) along with the greatest accuracy of 84.40% and area under receiver operating characteristic curve of 0.87. Conclusions: A computational pipeline using pre-procedural CT scans as inputs that outputs post-TAVR geometric and hemodynamic measurements was developed to assess metrics with the potential to predict the risk of HALT. Such a tool may help guide decision-making and understanding of prevention of postprocedural thrombosis.

Authors

Publication Details

Journal
JTCVS structural and endovascular.
Published
2024-12-24
DOI
https://doi.org/10.1016/j.xjse.2024.100041
Citations
2
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel computational method to predict hypoattenuated leaflet thickening post-transcatheter aortic valve replacement using preprocedural computed tomography scans

Jonathon A Leipsic, Vinod H. Thourani, Lakshmi Prasad Dasi, Philipp Ruile et al.
2 citations
JTCVS structural and endovascular.
Cardiac Valve Diseases and Treatments
0.80
article

A novel computational method to predict hypoattenuated leaflet thickening post-transcatheter aortic valve replacement using preprocedural computed tomography scans

Jonathon A Leipsic, Vinod H. Thourani, Lakshmi Prasad Dasi, Philipp Ruile, Noah Tregobov, Aniket Venkatesh, Gaurav Singh Gulsin, Fateme Esmailie, David Meier, Stephanie Sellers, Philipp Blanke, Hoda Hatoum, Beom Jun Lee, Breandan Yeats, Huang Chen, Franz‐Josef Neumann
article en
2 citations

Abstract

Objective: Hypoattenuated leaflet thickening (HALT) is a computed tomography (CT) finding after transcatheter aortic valve replacement (TAVR) that is indicative of bioprosthetic valvular thrombosis. There are currently no standardized or validated methods for predicting HALT, which can cause bioprosthetic valve dysfunction and has been associated with adverse patient outcomes. The objective was to develop a novel fast-response, artificial intelligence, and machine learning (ML)-driven computational pipeline to predict HALT using preprocedural CT scans. Methods: The pipeline consisted of (1) pre-TAVR CT reconstruction and reduced order modeling simulations to automatically predict postprocedural geometric parameters, (2) a landmark-guided automated left ventricle segmentation method to predict hemodynamic parameters, and (3) statistical and ML analyses to develop HALT predictive metrics. Results: Pre- and postprocedural scans from 45 patients (21 with HALT, 24 without) were used as inputs for the pipeline. We identified statistically significant relationships between HALT and peak systolic blood velocity (P < .01) and peak systolic blood flow through the bioprosthetic valve (P < .01), left ventricular ejection time (P < .01), ejection volume (P < .05), and right coronary height (P < .05). ML-yielded metrics related to circulation in the neosinuses correlated strongly with HALT occurrence (P < .001) along with the greatest accuracy of 84.40% and area under receiver operating characteristic curve of 0.87. Conclusions: A computational pipeline using pre-procedural CT scans as inputs that outputs post-TAVR geometric and hemodynamic measurements was developed to assess metrics with the potential to predict the risk of HALT. Such a tool may help guide decision-making and understanding of prevention of postprocedural thrombosis.

JTCVS structural and endovascular.Vol. 5
Zero hunger
Openalex Percentile: Top 22%
Cardiac Valve Diseases and Treatments
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.