Development of Control Method for Abration and Evaluation of Electrocautery Device Controller

The symmetrical impedance bridge, will be suggested to yield consistent and reliable results for measuring tissue damage during electrosurgical ablation. The methods that were identified as potentially viable for ablation detection were force and displacement measurements between the electrode tip and tissue surface. These were found to correlate tissue damage due to a high degree of variability in charge density caused by contact area variation. Another method, temperature measurement via thermistors, will be found to have a response time and a non-contact method will be examined with the size constraints. The last method will be to measure and correlate changes in the power output of the ESU to tissue damage. This method will be practically examined to measure and correlate to tissue damage due to ESU power output modulation. The changes in the tissue's electrical properties can be measured directly far more easily than measuring the power output. Correlation with tissue damage tended to be strong with an error range below what can be detectable by the human eye. But the high degree of variability in the mechanical properties of tissue makes the use of force and displacement measurements difficult to implement as part of a control method for ablation control.

Authors

Institutions

Publication Details

Journal
Journal of Modern Mechanical Engineering and Technology
Published
2024-12-24
DOI
https://doi.org/10.31875/2409-9848.2024.11.08
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Control Method for Abration and Evaluation of Electrocautery Device Controller

JungHun Choi
Journal of Modern Mechanical Engineering and Technology
Engineering Applied Research
article

Development of Control Method for Abration and Evaluation of Electrocautery Device Controller

JungHun Choi
article en

Abstract

The symmetrical impedance bridge, will be suggested to yield consistent and reliable results for measuring tissue damage during electrosurgical ablation. The methods that were identified as potentially viable for ablation detection were force and displacement measurements between the electrode tip and tissue surface. These were found to correlate tissue damage due to a high degree of variability in charge density caused by contact area variation. Another method, temperature measurement via thermistors, will be found to have a response time and a non-contact method will be examined with the size constraints. The last method will be to measure and correlate changes in the power output of the ESU to tissue damage. This method will be practically examined to measure and correlate to tissue damage due to ESU power output modulation. The changes in the tissue's electrical properties can be measured directly far more easily than measuring the power output. Correlation with tissue damage tended to be strong with an error range below what can be detectable by the human eye. But the high degree of variability in the mechanical properties of tissue makes the use of force and displacement measurements difficult to implement as part of a control method for ablation control.

Journal of Modern Mechanical Engineering and TechnologyVol. 11
Georgia Southern University (US)
Affordable and clean energy
Openalex Percentile: Top 73%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.