Effect of luminescent nanocrystal alignment on fluorescence anisotropy and light guiding in polymer films

Elongated semiconductor nanocrystals with oriented transition dipoles, such as nanorods (NRs) and elongated nanoplatelets (NPLs), can exhibit emission anisotropy when confined in thin films. In this work, we report the effect of nanocrystal alignment on thin polymer film optical properties including absorbance, fluorescence polarisation and light guiding. We find that changes in absorbance after stretching films containing elongated nanocrystals are associated with changes in nanocrystal alignment. Stretching the NPL films induces fluorescence anisotropy, which follows an exponential trend that can be approximated as linear within a moderate range of true strain values. This empirical relationship provides a means to monitor strain in polymers undergoing deformation. The light guiding properties of polymer films containing luminescent nanocrystals are also investigated by applying experimental and Monte Carlo simulation methodologies developed for the luminescent solar concentrator field. We show that drop cast polymer films containing spherical quantum dots, with isotropic fluorescence, more effectively guide light to the film edges compared with elongated nanocrystals. The elongated nanocrystals are aligned in the film plane by both stretching and drop casting processes, resulting in increased fluorescence emission from the film faces due to escape cone losses. • Drop casting and stretching align nanocrystals towards the plane in polymer films. • Nanocrystals are more aligned in stretched films than in drop cast films. • Relationship between true strain and fluorescence anisotropy is exponential. • Alignment of nanocrystals in cast and stretched films reduces light guiding. • Effect of nanocrystal alignment on light guiding is confirmed by optical modelling.

Authors

Institutions

Publication Details

Journal
Optical Materials
Published
2024-12-24
DOI
https://doi.org/10.1016/j.optmat.2024.116606
Citations
1
Primary Topic
Photochemistry and Electron Transfer Studies
Type
article
Field-Weighted Citation Impact
0.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of luminescent nanocrystal alignment on fluorescence anisotropy and light guiding in polymer films

Nicholas Kirkwood, Asaph Widmer‐Cooper, Marguerite Rinaudo, Yang Xu et al.
1 citations
Optical Materials
Photochemistry and Electron Transfer Studies
0.44
article

Effect of luminescent nanocrystal alignment on fluorescence anisotropy and light guiding in polymer films

Nicholas Kirkwood, Asaph Widmer‐Cooper, Marguerite Rinaudo, Yang Xu, Timothy Warner, Trevor A. Smith, Gary Rosengarten, Kenneth P. Ghiggino, Arun Ashokan, Jiho Han
article en
1 citations

Abstract

Elongated semiconductor nanocrystals with oriented transition dipoles, such as nanorods (NRs) and elongated nanoplatelets (NPLs), can exhibit emission anisotropy when confined in thin films. In this work, we report the effect of nanocrystal alignment on thin polymer film optical properties including absorbance, fluorescence polarisation and light guiding. We find that changes in absorbance after stretching films containing elongated nanocrystals are associated with changes in nanocrystal alignment. Stretching the NPL films induces fluorescence anisotropy, which follows an exponential trend that can be approximated as linear within a moderate range of true strain values. This empirical relationship provides a means to monitor strain in polymers undergoing deformation. The light guiding properties of polymer films containing luminescent nanocrystals are also investigated by applying experimental and Monte Carlo simulation methodologies developed for the luminescent solar concentrator field. We show that drop cast polymer films containing spherical quantum dots, with isotropic fluorescence, more effectively guide light to the film edges compared with elongated nanocrystals. The elongated nanocrystals are aligned in the film plane by both stretching and drop casting processes, resulting in increased fluorescence emission from the film faces due to escape cone losses. • Drop casting and stretching align nanocrystals towards the plane in polymer films. • Nanocrystals are more aligned in stretched films than in drop cast films. • Relationship between true strain and fluorescence anisotropy is exponential. • Alignment of nanocrystals in cast and stretched films reduces light guiding. • Effect of nanocrystal alignment on light guiding is confirmed by optical modelling.

Optical MaterialsVol. 159
The University of Sydney (AU), The University of Melbourne (AU), UNSW Sydney (AU), RMIT University (AU)
Centre of Excellence in Exciton Science
Openalex Percentile: Top 25%
Photochemistry and Electron Transfer Studies
0.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.