Flexural Behaviour of Non-Autoclaved Pre-Stressed High-Strength Concrete Pipe Piles with Different Rubber Contents

Non-autoclaved pre-stressed high-strength rubber-modified concrete (NA-PHRC) pipe piles were developed to address the high energy consumption and brittleness of existing pre-stressed high-strength concrete (PHC) pipe piles. The comparative flexural test results showed that the deformation capacity of NA-PHRC pipe piles improved, which was correlated with the rubber content. However, both the cracking moment and the ultimate moment decreased. When the rubber content is 5% and 10%, the cracking moment decreases by 3.85% and 7.69%, respectively, while the ultimate moment decreases by 3.75% and 7.28%. Additionally, the theoretical calculation results of the influence of rubber on the cracking and ultimate moments were consistent with the experimental results. Thus, this innovative NA-PHRC pipe pile can be applied in environments that require high durability.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-12-24
DOI
https://doi.org/10.3390/buildings15010012
Citations
1
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.26

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexural Behaviour of Non-Autoclaved Pre-Stressed High-Strength Concrete Pipe Piles with Different Rubber Contents

Ju Wen, Fei Yang, Xiaohui Li, Haofan Chen et al.
1 citations
Buildings
Geotechnical Engineering and Underground Structures
0.26
article

Flexural Behaviour of Non-Autoclaved Pre-Stressed High-Strength Concrete Pipe Piles with Different Rubber Contents

Ju Wen, Fei Yang, Xiaohui Li, Haofan Chen, Jia Liu, Dawei Chen, Feng Liu, Liang Xu, Gang Xu, Guangcheng Ding
article en
1 citations

Abstract

Non-autoclaved pre-stressed high-strength rubber-modified concrete (NA-PHRC) pipe piles were developed to address the high energy consumption and brittleness of existing pre-stressed high-strength concrete (PHC) pipe piles. The comparative flexural test results showed that the deformation capacity of NA-PHRC pipe piles improved, which was correlated with the rubber content. However, both the cracking moment and the ultimate moment decreased. When the rubber content is 5% and 10%, the cracking moment decreases by 3.85% and 7.69%, respectively, while the ultimate moment decreases by 3.75% and 7.28%. Additionally, the theoretical calculation results of the influence of rubber on the cracking and ultimate moments were consistent with the experimental results. Thus, this innovative NA-PHRC pipe pile can be applied in environments that require high durability.

BuildingsVol. 15(1)
Guangdong University of Technology (CN), Guangzhou Building Materials Institute (CN), Guangzhou Municipal Engineering Design and Research Institute (CN)
National Natural Science Foundation of China, Guangdong University of Technology
Affordable and clean energy
Openalex Percentile: Top 42%
Geotechnical Engineering and Underground Structures
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.