AN INNOVATIVE ECO-FRIENDLY TECHNIQUE TO MEASURE CHROMIUM WITH BENZOHYDRAZIDE

Numerous methodologies exist for trace level analysis of Chromium (Cr) metal ions. Many of these approaches are characterized by their time-consuming nature, complexity, toxicity, and sophistication. Recently, some spectrophotometric methods have been developed that, while less sensitive and selective, offer quicker analyses for determining Cr(III) ions. We innovated suitable, swift, sensitive and selective technique for detecting Cr(III) at trace levels, utilizing Benzohydrazide (BH) as the derivatizing reagent within a 3.0% Triton X-100 surfactant system. This procedure demonstrated improved analytical characteristics. Cr-[BH]3 complex exhibited absorbance maxima at λmax 436.2 nm at pH 5. The method adhered to Lambert-Beer’s law within concentration range of 0.1-4.0 μg/mL, with a 1:3 ligand to metal ratio achieved for the Cr-[BH]3 compound. Sandell's sensitivity was calculated to be 4.9 ng/cm², and the molar absorptivity was determined as ε = 4.03 × 10⁴ L mol⁻¹ cm⁻¹. A detection limit of 4.9 µg/L was successfully established. This method proved highly effective for quantifying Cr(III) ions across diverse samples, including natural, biological, alloy, industrial, and ecological matrices.

Authors

Institutions

Publication Details

Journal
Kashf Journal of Multidisciplinary Research
Published
2024-10-28
DOI
https://doi.org/10.71146/kjmr101
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AN INNOVATIVE ECO-FRIENDLY TECHNIQUE TO MEASURE CHROMIUM WITH BENZOHYDRAZIDE

Ghulam Abbas Shar, Gul Afshan Soomro, Muhammad Kashif Channa
Kashf Journal of Multidisciplinary Research
Analytical chemistry methods development
article

AN INNOVATIVE ECO-FRIENDLY TECHNIQUE TO MEASURE CHROMIUM WITH BENZOHYDRAZIDE

Ghulam Abbas Shar, Gul Afshan Soomro, Muhammad Kashif Channa
article en

Abstract

Numerous methodologies exist for trace level analysis of Chromium (Cr) metal ions. Many of these approaches are characterized by their time-consuming nature, complexity, toxicity, and sophistication. Recently, some spectrophotometric methods have been developed that, while less sensitive and selective, offer quicker analyses for determining Cr(III) ions. We innovated suitable, swift, sensitive and selective technique for detecting Cr(III) at trace levels, utilizing Benzohydrazide (BH) as the derivatizing reagent within a 3.0% Triton X-100 surfactant system. This procedure demonstrated improved analytical characteristics. Cr-[BH]3 complex exhibited absorbance maxima at λmax 436.2 nm at pH 5. The method adhered to Lambert-Beer’s law within concentration range of 0.1-4.0 μg/mL, with a 1:3 ligand to metal ratio achieved for the Cr-[BH]3 compound. Sandell's sensitivity was calculated to be 4.9 ng/cm², and the molar absorptivity was determined as ε = 4.03 × 10⁴ L mol⁻¹ cm⁻¹. A detection limit of 4.9 µg/L was successfully established. This method proved highly effective for quantifying Cr(III) ions across diverse samples, including natural, biological, alloy, industrial, and ecological matrices.

Kashf Journal of Multidisciplinary ResearchVol. 1(10)
Shah Abdul Latif University (PK)
Openalex Percentile: Top 77%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.