Ecological multivariate assisted spectrophotometric methods for determination of antipyrine and benzocaine HCl in presence of antipyrine official impurity and benzocaine HCl degradant: toward greenness and whiteness

A simple and green chemometrics-assisted spectrophotometric technique has beendeveloped and validated for the determination of antipyrine (ANT) and benzocaine HCl (BEN) along with the official impurity of ANT, antipyrine impurity A (ANT imp-A), and the degradation product of BEN, p-amino benzoic acid (PABA), in their quaternary mixture. Three models were developed and compared: partial least squares (PLS), artificial neural networks (ANN), and multivariate curve resolution-alternating least squares (MCR-ALS) where the four studied drugs were successfully quantified. The quantitative determination of the studied drugs was assessed using percentage recoveries, standard errors of prediction, and root mean square errors of prediction. The ANN model demonstrated the lowest error and the best correlation making it the most accurate method for analysis. The models were constructed in the ranges of 5.0-9.0 µg mL<sup>-1</sup> for ANT, 1.0-5.0 µg mL<sup>-1</sup> for BEN, 0.5-2.5 µg mL<sup>-1</sup> for ANT imp-A, and 0.25-1.25 µg mL<sup>-1</sup> for PABA. The established models successfully determined ANT, BEN, ANT imp-A, and PABA with detection limits of 0.312, 0.178, 0.093, and 0.042 µg mL<sup>-1</sup> for PLS, 0.185, 0.085, 0.001, and 0.034 µg mL<sup>-1</sup> for ANN; and 0.473, 0.240, 0.073, and 0.069 µg mL<sup>-1</sup> for MCR-ALS, respectively. The greenness and the whiteness of the proposed method were assessed using two green evaluating approaches: analytical Eco-scale, and AGREE, along with one white analytical chemistry evaluating tool, RGB. The three proposed models were successfully applied for determination of ANT and BEN in their pharmaceutically co-formulated dosage forms. They are also recommended for stability assays and purity testing of these drugs in quality control laboratories.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2024-12-24
DOI
https://doi.org/10.1186/s13065-024-01352-7
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ecological multivariate assisted spectrophotometric methods for determination of antipyrine and benzocaine HCl in presence of antipyrine official impurity and benzocaine HCl degradant: toward greenness and whiteness

Maha A. Hegazy, Amal M. Hassan, Khadiga M. Kelani, Ahmed H. Nadim
1 citations
BMC Chemistry
Electrochemical sensors and biosensors
0.21
article

Ecological multivariate assisted spectrophotometric methods for determination of antipyrine and benzocaine HCl in presence of antipyrine official impurity and benzocaine HCl degradant: toward greenness and whiteness

Maha A. Hegazy, Amal M. Hassan, Khadiga M. Kelani, Ahmed H. Nadim
article en
1 citations

Abstract

A simple and green chemometrics-assisted spectrophotometric technique has beendeveloped and validated for the determination of antipyrine (ANT) and benzocaine HCl (BEN) along with the official impurity of ANT, antipyrine impurity A (ANT imp-A), and the degradation product of BEN, p-amino benzoic acid (PABA), in their quaternary mixture. Three models were developed and compared: partial least squares (PLS), artificial neural networks (ANN), and multivariate curve resolution-alternating least squares (MCR-ALS) where the four studied drugs were successfully quantified. The quantitative determination of the studied drugs was assessed using percentage recoveries, standard errors of prediction, and root mean square errors of prediction. The ANN model demonstrated the lowest error and the best correlation making it the most accurate method for analysis. The models were constructed in the ranges of 5.0-9.0 µg mL<sup>-1</sup> for ANT, 1.0-5.0 µg mL<sup>-1</sup> for BEN, 0.5-2.5 µg mL<sup>-1</sup> for ANT imp-A, and 0.25-1.25 µg mL<sup>-1</sup> for PABA. The established models successfully determined ANT, BEN, ANT imp-A, and PABA with detection limits of 0.312, 0.178, 0.093, and 0.042 µg mL<sup>-1</sup> for PLS, 0.185, 0.085, 0.001, and 0.034 µg mL<sup>-1</sup> for ANN; and 0.473, 0.240, 0.073, and 0.069 µg mL<sup>-1</sup> for MCR-ALS, respectively. The greenness and the whiteness of the proposed method were assessed using two green evaluating approaches: analytical Eco-scale, and AGREE, along with one white analytical chemistry evaluating tool, RGB. The three proposed models were successfully applied for determination of ANT and BEN in their pharmaceutically co-formulated dosage forms. They are also recommended for stability assays and purity testing of these drugs in quality control laboratories.

BMC ChemistryVol. 18(1)
Cairo University (EG), Future University in Egypt (EG), Modern University for Information and Technology (EG)
Cairo University, Science and Technology Development Fund
Life in Land
Openalex Percentile: Top 45%
Electrochemical sensors and biosensors
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.