Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running

Somma, M and Lawrence, MA. Reliability and accuracy of Stryd to detect changes in vertical displacement of the center of mass while running. J Strength Cond Res 39(4): 414-417, 2025-The purpose of this study was to determine if Stryd can reliably and accurately detect changes in vertical displacement of the center of mass (VCoM) that are produced when cadence was increased by 5 and 10%. A secondary purpose of this investigation was to determine the interlimb reliability of Stryd for VCoM and cadence. Twenty healthy individuals (5 males, 15 females; age: 24.5 ± 1.5 years; mass: 67.1 ± 12.2 kg; height: 1.66 ± 0.01 m) were fitted for motion capture and 2 Stryd devices. After warm-up, subjects ran at a self-selected speed on the treadmill for each condition (self-selected, +5%, and +10% cadence) while VCoM and cadence were collected simultaneously from Stryd and motion capture. Reliability between the Stryd devices on different limbs was excellent for both cadence (intraclass correlation coefficient [ICC] = 0.999, p < 0.001) and VCoM (ICC = 0.993, p < 0.001). Cadence was not significantly different between the Stryd device and motion capture ( p = 0.153). Stryd produced significantly ( p < 0.001) smaller values for VCoM regardless of condition, with average differences ranging between 4.4 and 4.6 cm. A linear regression revealed that Stryd predicted 50.7% of variation in motion capture VCoM ( p < 0.001). Stryd can reliably measure both cadence and VCoM regardless of which limb it is placed on, as indicated by the near-perfect agreement between Stryd devices, and the Stryd device can detect and predict changes in VCoM. However, Stryd consistently underestimates VCoM, which can be corrected by using a linear regression equation.

Authors

Institutions

Publication Details

Journal
The Journal of Strength and Conditioning Research
Published
2024-12-24
DOI
https://doi.org/10.1519/jsc.0000000000005038
Primary Topic
Winter Sports Injuries and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running

Michael A. Lawrence, Matthew Somma
The Journal of Strength and Conditioning Research
Winter Sports Injuries and Performance
article

Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running

Michael A. Lawrence, Matthew Somma
article en

Abstract

Somma, M and Lawrence, MA. Reliability and accuracy of Stryd to detect changes in vertical displacement of the center of mass while running. J Strength Cond Res 39(4): 414-417, 2025-The purpose of this study was to determine if Stryd can reliably and accurately detect changes in vertical displacement of the center of mass (VCoM) that are produced when cadence was increased by 5 and 10%. A secondary purpose of this investigation was to determine the interlimb reliability of Stryd for VCoM and cadence. Twenty healthy individuals (5 males, 15 females; age: 24.5 ± 1.5 years; mass: 67.1 ± 12.2 kg; height: 1.66 ± 0.01 m) were fitted for motion capture and 2 Stryd devices. After warm-up, subjects ran at a self-selected speed on the treadmill for each condition (self-selected, +5%, and +10% cadence) while VCoM and cadence were collected simultaneously from Stryd and motion capture. Reliability between the Stryd devices on different limbs was excellent for both cadence (intraclass correlation coefficient [ICC] = 0.999, p < 0.001) and VCoM (ICC = 0.993, p < 0.001). Cadence was not significantly different between the Stryd device and motion capture ( p = 0.153). Stryd produced significantly ( p < 0.001) smaller values for VCoM regardless of condition, with average differences ranging between 4.4 and 4.6 cm. A linear regression revealed that Stryd predicted 50.7% of variation in motion capture VCoM ( p < 0.001). Stryd can reliably measure both cadence and VCoM regardless of which limb it is placed on, as indicated by the near-perfect agreement between Stryd devices, and the Stryd device can detect and predict changes in VCoM. However, Stryd consistently underestimates VCoM, which can be corrected by using a linear regression equation.

The Journal of Strength and Conditioning ResearchVol. 39(4)
University of New England (US)
Openalex Percentile: Top 57%
Winter Sports Injuries and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reliability and Accuracy of Stryd to Detect Changes in Vertical Displacement of the Center of Mass While Running — Michael A. Lawrence, Matthew Somma · The Journal of Strength and Conditioning Research (2024) | TGRS Research Map | TGRS