Microspectrometer-Enabled Real-Time Concentration Monitoring in the Microfluidic Protein Enrichment Chip

This study presents a novel microspectrometer-integrated microfluidic system for real-time protein concentration monitoring. The device employs electrokinetic principles for efficient protein preconcentration in a PDMS and Nafion film channel. Using FITC-labeled BSA as a model protein, the system demonstrated a linear correlation between protein concentration and absorbance at 491 nm. Notably, it achieved a 833-fold concentration increase from an initial 10 nM within 20 min. The compact microspectrometer system offers enhanced accuracy and sensitivity compared to traditional fluorescence microscopy methods. This innovation presents a promising solution for portable and point-of-care diagnostic applications, facilitating timely disease detection and monitoring. The findings highlight the potential for this technology to advance protein analysis and biomarker discovery in clinical settings, potentially improving patient outcomes through enhanced diagnostic capabilities.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2024-12-24
DOI
https://doi.org/10.3390/bios15010001
Citations
3
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microspectrometer-Enabled Real-Time Concentration Monitoring in the Microfluidic Protein Enrichment Chip

Yahui Wu, Dongli Li, Chun‐Ping Jen, Wenshu Huang
3 citations
Biosensors
Microfluidic and Bio-sensing Technologies
0.55
article

Microspectrometer-Enabled Real-Time Concentration Monitoring in the Microfluidic Protein Enrichment Chip

Yahui Wu, Dongli Li, Chun‐Ping Jen, Wenshu Huang
article en
3 citations

Abstract

This study presents a novel microspectrometer-integrated microfluidic system for real-time protein concentration monitoring. The device employs electrokinetic principles for efficient protein preconcentration in a PDMS and Nafion film channel. Using FITC-labeled BSA as a model protein, the system demonstrated a linear correlation between protein concentration and absorbance at 491 nm. Notably, it achieved a 833-fold concentration increase from an initial 10 nM within 20 min. The compact microspectrometer system offers enhanced accuracy and sensitivity compared to traditional fluorescence microscopy methods. This innovation presents a promising solution for portable and point-of-care diagnostic applications, facilitating timely disease detection and monitoring. The findings highlight the potential for this technology to advance protein analysis and biomarker discovery in clinical settings, potentially improving patient outcomes through enhanced diagnostic capabilities.

BiosensorsVol. 15(1)
National Chung Cheng University (TW), Kaohsiung Medical University (TW), Jimei University (CN)
National Science and Technology Council
Industry, innovation and infrastructure
Openalex Percentile: Top 35%
Microfluidic and Bio-sensing Technologies
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.