Systematic Evaluation of IMU Sensors for Application in Smart Glove System for Remote Monitoring of Hand Differences

Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (<i>p</i> > 0.95 across all tests). Agreement matrices revealed high agreement (<1°) in 24 trials, moderate (1-10°) in 12 trials, and low (>10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0-90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-24
DOI
https://doi.org/10.3390/s25010002
Citations
5
Primary Topic
Cerebral Palsy and Movement Disorders
Type
article
Field-Weighted Citation Impact
1.93

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Systematic Evaluation of IMU Sensors for Application in Smart Glove System for Remote Monitoring of Hand Differences

Anne Harrison, Ali Jabran, Antonio Fratini, Surej Mouli et al.
5 citations
Sensors
Cerebral Palsy and Movement Disorders
1.93
article

Systematic Evaluation of IMU Sensors for Application in Smart Glove System for Remote Monitoring of Hand Differences

Anne Harrison, Ali Jabran, Antonio Fratini, Surej Mouli, Andrea Jester
article en
5 citations

Abstract

Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation. However, current clinical methods rely on subjective observations and limited tests. Smart gloves with inertial measurement unit (IMU) sensors have emerged as tools for capturing digit movements, yet their sensor accuracy remains underexplored. This study developed and validated an IMU-based smart glove system for measuring finger joint movements in individuals with hand differences. The glove measured 3D digit rotations and was evaluated against an industrial robotic arm. Tests included rotations around three axes at 1°, 10°, and 90°, simulating extension/flexion, supination/pronation, and abduction/adduction. The IMU sensors demonstrated high accuracy and reliability, with minimal systematic bias and strong positive correlations (<i>p</i> > 0.95 across all tests). Agreement matrices revealed high agreement (<1°) in 24 trials, moderate (1-10°) in 12 trials, and low (>10°) in only 4 trials. The Root Mean Square Error (RMSE) ranged from 1.357 to 5.262 for the 90° tests, 0.094 to 0.538 for the 10° tests, and 0.129 to 0.36 for the 1° tests. Likewise, mean absolute error (MAE) ranged from 0.967 to 4.679 for the 90° tests, 0.073 to 0.386 for the 10° tests, and 0.102 to 0.309 for the 1° tests. The sensor provided precise measurements of digit angles across 0-90° in multiple directions, enabling reliable clinical assessment, remote monitoring, and improved diagnosis, treatment, and rehabilitation for individuals with hand differences.

SensorsVol. 25(1)
Aston University (GB), Birmingham Children's Hospital (GB)
Aston University, Engineering and Physical Sciences Research Council
Peace, Justice and strong institutions
Openalex Percentile: Top 12%
Cerebral Palsy and Movement Disorders
1.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.