Silicone Loss During Histological Preparation of Breast Implant Tissue From Capsular Contracture, Quantified by Stimulated Raman Scattering Microscopy

Breast augmentations, commonly performed for aesthetic or medical reasons, often use silicone (polydimethylsiloxane [PDMS]) implants. Some patients develop complications like capsular contracture, where scar tissue forms around the implant. Previously, we used stimulated Raman scattering (SRS) microscopy to detect and quantify silicone in stained capsule tissue, finding a correlation between silicone amount and contracture severity. However, we suspected silicone loss during histological preparation, which includes multiple steps like formalin fixation and paraffin embedding. In this study, we assessed silicone loss by comparing adjacent tissue samples from the same capsule: one prepared conventionally and the other snap-frozen. SRS microscopy revealed that snap-frozen samples had roughly five times more silicone, indicating significant silicone loss during conventional preparation. Thus, measuring silicone in histologically prepared samples likely underestimates PDMS content.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2024-12-23
DOI
https://doi.org/10.1002/jbio.202400415
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silicone Loss During Histological Preparation of Breast Implant Tissue From Capsular Contracture, Quantified by Stimulated Raman Scattering Microscopy

Freek Ariese, Robert W. Schmidt, Erik de Bakker
1 citations
Journal of Biophotonics
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
article

Silicone Loss During Histological Preparation of Breast Implant Tissue From Capsular Contracture, Quantified by Stimulated Raman Scattering Microscopy

Freek Ariese, Robert W. Schmidt, Erik de Bakker
article en
1 citations

Abstract

Breast augmentations, commonly performed for aesthetic or medical reasons, often use silicone (polydimethylsiloxane [PDMS]) implants. Some patients develop complications like capsular contracture, where scar tissue forms around the implant. Previously, we used stimulated Raman scattering (SRS) microscopy to detect and quantify silicone in stained capsule tissue, finding a correlation between silicone amount and contracture severity. However, we suspected silicone loss during histological preparation, which includes multiple steps like formalin fixation and paraffin embedding. In this study, we assessed silicone loss by comparing adjacent tissue samples from the same capsule: one prepared conventionally and the other snap-frozen. SRS microscopy revealed that snap-frozen samples had roughly five times more silicone, indicating significant silicone loss during conventional preparation. Thus, measuring silicone in histologically prepared samples likely underestimates PDMS content.

Journal of BiophotonicsVol. 18(2)
Amsterdam University Medical Centers (NL), Vrije Universiteit Amsterdam (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Ministry of Economic Affairs
Openalex Percentile: Top 18%
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.