Non-invasive TensorTip MTX Hemoglobin Measurement Validation Study

zObjective: Point of care devices are fast and easy to use but their true potential is still waiting to come up.TensorTip MTX is a non-invasive medical device can measure various bioparameters, including hemoglobin.Purpose of this study is to measure the correlation between TensorTip MTX and our routine laboratuvary analysis of hemoglobin and to see that device is useable in emergency department settings for situations like gastroinstestinal bleeding and acute traumatic hemorrhages. Methods:In the month after the ethical board approval, we conduct our study in 147 patients.Their hemoglobin levels were already measured while their course of emergency department visit.To gather accurate data of hemoglobin measurement of TensorTip MTX, device put on the ring finger of the patients and wait at least 45 seconds for measurement.All measurement documented and recorded by researcher.Measurements from blood samples and TensorTip MTX device are compared with intraclass correlation coefficient (ICC) and Pearson correlation coefficient. Results:In 147 patients; 61.2% (n=90) were male, 38.8% (n=57) were female and ages are between 18 and 89.Mean age is 55.7220.30years; 23.1% (n=34) of them is under 35 years old, 76.9% (n=113) over 35 years.Statistically, the correlation between hemoglobin levels measured by the reference method and TensorTip was found to be 42.4%, which is statistically signficant (p=0.001;p<0.01) [ICC: 0.424; 95% confidence interval (CI): 0.281-0.548].Correlation between hematocrit level measurements is 46.9% significantly compatible (p=0.001;p<0.01) (ICC: 0.429; 95% CI: 0.333-0.586). Conclusion:Our study showed that correlation between reference measurement and TensorTip MTX device is fair (ICC: 0.424 for hemoglobin and 0.429 for hematocrit).Further studies needed to determine that this device is suitable or not to identify the need of blood transfusion and management of patients with acute hemorrhages in the emergency settings for now.

Authors

Institutions

Publication Details

Journal
The Anatolian Journal of General Medical Research
Published
2024-12-23
DOI
https://doi.org/10.4274/anatoljmed.2024.61587
Primary Topic
Electron Spin Resonance Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-invasive TensorTip MTX Hemoglobin Measurement Validation Study

Özlem Güneysel, Fatma Sarı Doğan, Eren Gökdağ, Gülbin Aydoğdu Umaç
The Anatolian Journal of General Medical Research
Electron Spin Resonance Studies
article

Non-invasive TensorTip MTX Hemoglobin Measurement Validation Study

Özlem Güneysel, Fatma Sarı Doğan, Eren Gökdağ, Gülbin Aydoğdu Umaç
article en

Abstract

zObjective: Point of care devices are fast and easy to use but their true potential is still waiting to come up.TensorTip MTX is a non-invasive medical device can measure various bioparameters, including hemoglobin.Purpose of this study is to measure the correlation between TensorTip MTX and our routine laboratuvary analysis of hemoglobin and to see that device is useable in emergency department settings for situations like gastroinstestinal bleeding and acute traumatic hemorrhages. Methods:In the month after the ethical board approval, we conduct our study in 147 patients.Their hemoglobin levels were already measured while their course of emergency department visit.To gather accurate data of hemoglobin measurement of TensorTip MTX, device put on the ring finger of the patients and wait at least 45 seconds for measurement.All measurement documented and recorded by researcher.Measurements from blood samples and TensorTip MTX device are compared with intraclass correlation coefficient (ICC) and Pearson correlation coefficient. Results:In 147 patients; 61.2% (n=90) were male, 38.8% (n=57) were female and ages are between 18 and 89.Mean age is 55.7220.30years; 23.1% (n=34) of them is under 35 years old, 76.9% (n=113) over 35 years.Statistically, the correlation between hemoglobin levels measured by the reference method and TensorTip was found to be 42.4%, which is statistically signficant (p=0.001;p<0.01) [ICC: 0.424; 95% confidence interval (CI): 0.281-0.548].Correlation between hematocrit level measurements is 46.9% significantly compatible (p=0.001;p<0.01) (ICC: 0.429; 95% CI: 0.333-0.586). Conclusion:Our study showed that correlation between reference measurement and TensorTip MTX device is fair (ICC: 0.424 for hemoglobin and 0.429 for hematocrit).Further studies needed to determine that this device is suitable or not to identify the need of blood transfusion and management of patients with acute hemorrhages in the emergency settings for now.

The Anatolian Journal of General Medical ResearchVol. 34(3)
Izmir University (TR), Sağlık Bilimleri Üniversitesi (TR), Fatih Sultan Mehmet Eğitim Ve Araştırma Hastanesi (TR), Istanbul University (TR)
Zero hunger
Openalex Percentile: Top 85%
Electron Spin Resonance Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.