Practical parameters for extending the velocity range when applying a partial inversion pulse to the ultrasonic time-domain cross-correlation method

Abstract This paper describes a method to reduce false velocity detection by applying a partial inversion pulse (PIP) to the ultrasonic time-domain cross-correlation (UTDC) method. False detection occurs when we attempt to expand the velocity range of UTDC (same as the aliasing limit of the pulsed Doppler method). Specifically, the effects of three parameters that are important for practical use and have not been discussed before were examined, and recommended values for them were determined. The UTDC method can obtain the flow velocity profile along an ultrasonic beam by transmitting and receiving pulses. The PIP is a waveform that is phase-inverted within a pulse that is half as short as a conventional waveform, and it can reduce false detection by simply applying to the UTDC method. The three important parameters are the width of the reference window, the number density of reflective particles in the measurement volume, and the threshold for the cross-correlation coefficient. The PIP waveform was modeled, and the influences of these parameters were evaluated by simulations that calculate the correlation coefficient for single pulses and for waveforms overlapped with up to three pulses. In addition, the method was also experimentally verified in a pipe flow. Tests were also carried out with various number densities of reflectors. From these results, the effect of applying the PIP was confirmed for all values of these parameters. Specifically, the PIP can shift and reduce the peak of the first sidelobe in the correlation coefficient. As recommended values for each parameter, the experimental results showed that the width of the reference window should be equal to the pulse width, the number density of reflectors should be about one in the measurement volume, and the threshold value of the correlation coefficient should be about 0.5–0.7.

Authors

Publication Details

Journal
Measurement Science and Technology
Published
2024-12-23
DOI
https://doi.org/10.1088/1361-6501/ad9ca8
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical parameters for extending the velocity range when applying a partial inversion pulse to the ultrasonic time-domain cross-correlation method

Noriyuki Furuichi, Sanehiro Wada
Measurement Science and Technology
Flow Measurement and Analysis
article

Practical parameters for extending the velocity range when applying a partial inversion pulse to the ultrasonic time-domain cross-correlation method

Noriyuki Furuichi, Sanehiro Wada
article en

Abstract

Abstract This paper describes a method to reduce false velocity detection by applying a partial inversion pulse (PIP) to the ultrasonic time-domain cross-correlation (UTDC) method. False detection occurs when we attempt to expand the velocity range of UTDC (same as the aliasing limit of the pulsed Doppler method). Specifically, the effects of three parameters that are important for practical use and have not been discussed before were examined, and recommended values for them were determined. The UTDC method can obtain the flow velocity profile along an ultrasonic beam by transmitting and receiving pulses. The PIP is a waveform that is phase-inverted within a pulse that is half as short as a conventional waveform, and it can reduce false detection by simply applying to the UTDC method. The three important parameters are the width of the reference window, the number density of reflective particles in the measurement volume, and the threshold for the cross-correlation coefficient. The PIP waveform was modeled, and the influences of these parameters were evaluated by simulations that calculate the correlation coefficient for single pulses and for waveforms overlapped with up to three pulses. In addition, the method was also experimentally verified in a pipe flow. Tests were also carried out with various number densities of reflectors. From these results, the effect of applying the PIP was confirmed for all values of these parameters. Specifically, the PIP can shift and reduce the peak of the first sidelobe in the correlation coefficient. As recommended values for each parameter, the experimental results showed that the width of the reference window should be equal to the pulse width, the number density of reflectors should be about one in the measurement volume, and the threshold value of the correlation coefficient should be about 0.5–0.7.

Measurement Science and TechnologyVol. 36(1)
Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 73%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.