Development and Validation of a New Adherence Scale for Antiseizure Medications [ASASM]

<b>Objective:</b> The objective was to develop and validate a multidimensional scale that measures adherence levels to antiseizure medications and detects patients' reasons for non-adherence. <b>Methods:</b> A new scale was developed, namely the "Adherence Scale for Anti-Seizure Medication(s)-10 items [ASASM-10]". It consists of ten statements that cover different causes of non-adherence to antiseizure medications. The domain selection was based on a comprehensive literature review. Guidelines for constructing an effective scale were followed to write the statements. Three independent expert judges assessed the content validity of the scale. The reliability of ASASM-10 was tested using three methods: internal consistency measurement (Cronbach's alpha), Intraclass Correlation Coefficient [ICC] with a 95% Confidence Interval [95% CI], and test-retest reliability. Validity was tested using Principal Component Analysis [PCA] and a correlation coefficient. PCA was applied after measuring sampling adequacy via Kaiser-Meyer-Olkin [KMO] and Bartlett's sphericity. The Medication Adherence Rating Scale [MARS] was selected as a pre-existing self-report method for validation of this new scale. <b>Results:</b> A total of 162 patients completed the study scales (mean ages ± SD: 34.07 ± 10.406 years). The scale demonstrated a good internal consistency with Cronbach's alpha coefficient of 0.80 and exceeded the required value (i.e., 0.70) for the reliability of new scales. ASASM-10 showed a satisfactory ICC (95% CI) of 0.799 (0.718-0.857), <i>p</i>-value < 0.001. The test-retest reliability demonstrated a good correlation of ρ = 0.648, <i>p</i>-value < 0.001. The construct validity assessed by PCA retained four components as their eigenvalues exceeded one. The correlation coefficient demonstrated a positive moderate correlation between ASASM-10 and MARS (ρ = 0.283), <i>p</i>-value < 0.001. <b>Conclusions:</b> The present analyses provided evidence that ASASM-10 is a reliable and valid scale for evaluating patients' adherence to antiseizure medications. It is the first available scale for assessing medication adherence in patients with epilepsy that can be utilized in clinical practice and research settings.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-12-23
DOI
https://doi.org/10.3390/jcm13247844
Primary Topic
Medication Adherence and Compliance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a New Adherence Scale for Antiseizure Medications [ASASM]

Bshra Ali A. Alsfouk, Sarah A. Alotaibi, Layla N. Alanizy, Noura A. Alrukban et al.
Journal of Clinical Medicine
Medication Adherence and Compliance
article

Development and Validation of a New Adherence Scale for Antiseizure Medications [ASASM]

Bshra Ali A. Alsfouk, Sarah A. Alotaibi, Layla N. Alanizy, Noura A. Alrukban, Ahmad Saleh
article en

Abstract

<b>Objective:</b> The objective was to develop and validate a multidimensional scale that measures adherence levels to antiseizure medications and detects patients' reasons for non-adherence. <b>Methods:</b> A new scale was developed, namely the "Adherence Scale for Anti-Seizure Medication(s)-10 items [ASASM-10]". It consists of ten statements that cover different causes of non-adherence to antiseizure medications. The domain selection was based on a comprehensive literature review. Guidelines for constructing an effective scale were followed to write the statements. Three independent expert judges assessed the content validity of the scale. The reliability of ASASM-10 was tested using three methods: internal consistency measurement (Cronbach's alpha), Intraclass Correlation Coefficient [ICC] with a 95% Confidence Interval [95% CI], and test-retest reliability. Validity was tested using Principal Component Analysis [PCA] and a correlation coefficient. PCA was applied after measuring sampling adequacy via Kaiser-Meyer-Olkin [KMO] and Bartlett's sphericity. The Medication Adherence Rating Scale [MARS] was selected as a pre-existing self-report method for validation of this new scale. <b>Results:</b> A total of 162 patients completed the study scales (mean ages ± SD: 34.07 ± 10.406 years). The scale demonstrated a good internal consistency with Cronbach's alpha coefficient of 0.80 and exceeded the required value (i.e., 0.70) for the reliability of new scales. ASASM-10 showed a satisfactory ICC (95% CI) of 0.799 (0.718-0.857), <i>p</i>-value < 0.001. The test-retest reliability demonstrated a good correlation of ρ = 0.648, <i>p</i>-value < 0.001. The construct validity assessed by PCA retained four components as their eigenvalues exceeded one. The correlation coefficient demonstrated a positive moderate correlation between ASASM-10 and MARS (ρ = 0.283), <i>p</i>-value < 0.001. <b>Conclusions:</b> The present analyses provided evidence that ASASM-10 is a reliable and valid scale for evaluating patients' adherence to antiseizure medications. It is the first available scale for assessing medication adherence in patients with epilepsy that can be utilized in clinical practice and research settings.

Journal of Clinical MedicineVol. 13(24)
Princess Nourah bint Abdulrahman University (SA), King Fahd Medical City (SA)
Princess Nourah Bint Abdulrahman University, Tanta University, King Fahad Medical City
Openalex Percentile: Top 71%
Medication Adherence and Compliance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.