14-MeV and Atmospheric Neutron Monitoring Through Optical Fiber Dosimeters

Radiation-induced attenuation (RIA)-based dosimetry exploiting phosphosilicate optical fiber (OF) has been established as a reliable and precise dosimetry technique, to monitor the total ionizing dose (TID) in a variety of harsh environments. We evaluate here the potential of this technology to monitor 14-MeV and atmospheric neutrons. Experiments performed at the TRIUMF Neutron Facility (TNF) from TRIUMF and Frascati neutron generator (FNG) from ENEA demonstrate that after calibration, the fiber dosimeter can serve as an efficient fluence monitor, with the RIA being linearly dependent on the neutron fluence. Using Geant4 simulations, we show that the radiation sensitivity of the fiber, around 3.5 dB <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> km<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${}^{-1}~\cdot $ </tex-math></inline-formula> Gy−1 for 14-MeV neutrons, agrees with the ones found in previous studies for photons and protons. For atmospheric neutrons, the calibration differs by a factor of up to 2.5 with respect to the usual factor. Extensive simulations are performed showing that in these neutron environments, the consideration of the real 3-D structure of the fiber coil is mandatory for a fine calibration of the dosimeter. Perspectives for fiber dosimetry of neutron-rich environments are then discussed.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-12-23
DOI
https://doi.org/10.1109/tns.2024.3521506
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

14-MeV and Atmospheric Neutron Monitoring Through Optical Fiber Dosimeters

M. Roche, Y. Ouerdane, Damien Lambert, Julien Mekki et al.
1 citations
IEEE Transactions on Nuclear Science
Radiation Therapy and Dosimetry
0.42
article

14-MeV and Atmospheric Neutron Monitoring Through Optical Fiber Dosimeters

M. Roche, Y. Ouerdane, Damien Lambert, Julien Mekki, Philippe Paillet, Cornelia Hoehr, A. Colangeli, Luca Weninger, A. Boukenter, Emmanuel Marin, M. Trinczek, Adriana Morana, Thierry Robin, Sylvain Girard, C. Bélanger-Champagne, Nourdine Kerboub
article en
1 citations

Abstract

Radiation-induced attenuation (RIA)-based dosimetry exploiting phosphosilicate optical fiber (OF) has been established as a reliable and precise dosimetry technique, to monitor the total ionizing dose (TID) in a variety of harsh environments. We evaluate here the potential of this technology to monitor 14-MeV and atmospheric neutrons. Experiments performed at the TRIUMF Neutron Facility (TNF) from TRIUMF and Frascati neutron generator (FNG) from ENEA demonstrate that after calibration, the fiber dosimeter can serve as an efficient fluence monitor, with the RIA being linearly dependent on the neutron fluence. Using Geant4 simulations, we show that the radiation sensitivity of the fiber, around 3.5 dB <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\cdot $ </tex-math></inline-formula> km<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${}^{-1}~\cdot $ </tex-math></inline-formula> Gy−1 for 14-MeV neutrons, agrees with the ones found in previous studies for photons and protons. For atmospheric neutrons, the calibration differs by a factor of up to 2.5 with respect to the usual factor. Extensive simulations are performed showing that in these neutron environments, the consideration of the real 3-D structure of the fiber coil is mandatory for a fine calibration of the dosimeter. Perspectives for fiber dosimetry of neutron-rich environments are then discussed.

IEEE Transactions on Nuclear ScienceVol. 72(4)
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), TRIUMF (CA), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Centre National d'Études Spatiales (FR), Laboratoire Hubert Curien (FR), CEA DAM Île-de-France (FR), Centre Hospitalier Lannion Trestel (FR), European Organization for Nuclear Research (CH)
Affordable and clean energy
Openalex Percentile: Top 29%
Radiation Therapy and Dosimetry
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.