A Portable Chip-Based Overhauser DNP Platform for Biomedical Liquid Sample Analysis

Low-field nuclear magnetic resonance (NMR) instruments are an indispensable tool in industrial research and quality control. However, the intrinsically low spin polarization at low magnetic fields severely limits their detection sensitivity and measurement throughput, preventing their widespread use in biomedical analysis. Overhauser dynamic nuclear polarization (ODNP) effectively addresses this problem by transferring the spin polarization from free electrons to protons, significantly enhancing sensitivity. In this paper, we explore the potential of using ODNP for signal enhancement in a custom-designed portable chip-based DNP-enhanced NMR platform, which is centered around a miniaturized microwave (MW) transmitter, a custom-designed NMR-on-a-chip transceiver, and two application-specific ODNP probes. The MW transmitter provides frequency synthesis, signal modulation, and power amplification, providing sufficient output power for efficient polarization transfer. The NMR-on-a-chip transceiver combines a radio frequency (RF) transmitter with a fully differential quadrature receiver, providing pulsed excitation and NMR signal down-conversion and amplification. Two custom-designed ODNP probes are used for proof-of-concept DNP-enhanced NMR relaxometry and spectroscopy measurements. The presented chip-based ODNP platform achieves a maximum MW output power of , resulting in a signal enhancement of using the relaxometry ODNP probe with of non-degassed TEMPOL solution, and an enhancement of with the spectroscopy ODNP probe using of the same solution. The proton polarization was increased from to at a low field of . Proof-of-concept measurements on radical-doped tattoo inks and acetic acid verify the potential of our chip-based ODNP platform for the analysis of biologically and medically relevant parameters such as relaxation times, chemical shifts, and hyperfine interactions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2024-12-23
DOI
https://doi.org/10.1109/tbcas.2024.3521033
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Portable Chip-Based Overhauser DNP Platform for Biomedical Liquid Sample Analysis

Frederik Dreyer, Michal Kern, Hadi Lotfi, Qing Yang et al.
IEEE Transactions on Biomedical Circuits and Systems
Analog and Mixed-Signal Circuit Design
article

A Portable Chip-Based Overhauser DNP Platform for Biomedical Liquid Sample Analysis

Frederik Dreyer, Michal Kern, Hadi Lotfi, Qing Yang, Bernhard Blümich, Jens Anders
article en

Abstract

Low-field nuclear magnetic resonance (NMR) instruments are an indispensable tool in industrial research and quality control. However, the intrinsically low spin polarization at low magnetic fields severely limits their detection sensitivity and measurement throughput, preventing their widespread use in biomedical analysis. Overhauser dynamic nuclear polarization (ODNP) effectively addresses this problem by transferring the spin polarization from free electrons to protons, significantly enhancing sensitivity. In this paper, we explore the potential of using ODNP for signal enhancement in a custom-designed portable chip-based DNP-enhanced NMR platform, which is centered around a miniaturized microwave (MW) transmitter, a custom-designed NMR-on-a-chip transceiver, and two application-specific ODNP probes. The MW transmitter provides frequency synthesis, signal modulation, and power amplification, providing sufficient output power for efficient polarization transfer. The NMR-on-a-chip transceiver combines a radio frequency (RF) transmitter with a fully differential quadrature receiver, providing pulsed excitation and NMR signal down-conversion and amplification. Two custom-designed ODNP probes are used for proof-of-concept DNP-enhanced NMR relaxometry and spectroscopy measurements. The presented chip-based ODNP platform achieves a maximum MW output power of , resulting in a signal enhancement of using the relaxometry ODNP probe with of non-degassed TEMPOL solution, and an enhancement of with the spectroscopy ODNP probe using of the same solution. The proton polarization was increased from to at a low field of . Proof-of-concept measurements on radical-doped tattoo inks and acetic acid verify the potential of our chip-based ODNP platform for the analysis of biologically and medically relevant parameters such as relaxation times, chemical shifts, and hyperfine interactions.

IEEE Transactions on Biomedical Circuits and SystemsVol. 19(2)
University of Stuttgart (DE), RWTH Aachen University (DE)
Openalex Percentile: Top 78%
Analog and Mixed-Signal Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.