Sensitivity Analysis of Different Controller Parameters on the Stability of the Weak-Grid-Tied Interlinking VSC

The stability problem arising from the DC-link voltage outer loop and current inner loop control in weak-grid-tied interlinking voltage-source converters (VSC) system has been extensively investigated. However, the different impacts on system stability caused by these controller parameters have not been well solved. A three-port hybrid AC/DC admittance-based model for VSC taking into account AC- and DC-side dynamics is developed for revealing the mechanism intuitively on the formation of the positive and negative feedback effects in the DC-link voltage control loop. Subsequently, the stability characteristics of the voltage outer loop and current inner loop controller parameters on VSC are analyzed. Compared to adjusting the voltage outer loop controller parameters which has significant effort on the dynamic regulation characteristics, it is more sensitive on system stability by the parameter change of the current inner loop controller. Theoretical results, along with experimental verification, are provided to validate the analysis.

Authors

Institutions

Publication Details

Journal
Protection and Control of Modern Power Systems
Published
2024-12-23
DOI
https://doi.org/10.23919/pcmp.2023.000303
Citations
4
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity Analysis of Different Controller Parameters on the Stability of the Weak-Grid-Tied Interlinking VSC

Zhiwei Zeng, Sujie Zhang, Ling Mao, Jinbin Zhao et al.
4 citations
Protection and Control of Modern Power Systems
HVDC Systems and Fault Protection
0.83
article

Sensitivity Analysis of Different Controller Parameters on the Stability of the Weak-Grid-Tied Interlinking VSC

Zhiwei Zeng, Sujie Zhang, Ling Mao, Jinbin Zhao, Keqing Qu
article en
4 citations

Abstract

The stability problem arising from the DC-link voltage outer loop and current inner loop control in weak-grid-tied interlinking voltage-source converters (VSC) system has been extensively investigated. However, the different impacts on system stability caused by these controller parameters have not been well solved. A three-port hybrid AC/DC admittance-based model for VSC taking into account AC- and DC-side dynamics is developed for revealing the mechanism intuitively on the formation of the positive and negative feedback effects in the DC-link voltage control loop. Subsequently, the stability characteristics of the voltage outer loop and current inner loop controller parameters on VSC are analyzed. Compared to adjusting the voltage outer loop controller parameters which has significant effort on the dynamic regulation characteristics, it is more sensitive on system stability by the parameter change of the current inner loop controller. Theoretical results, along with experimental verification, are provided to validate the analysis.

Protection and Control of Modern Power SystemsVol. 10(1)
Shanghai University of Electric Power (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 26%
HVDC Systems and Fault Protection
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.