Evaluation of Retentive Forces in Three Types of Removable Partial Denture Framework Materials: An In Vitro Study

Introduction The utilization of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in the production of polyetheretherketone (PEEK) and acetal frameworks enhances the precision and stability of partial denture frameworks. This study evaluates the retentive forces of CAD/CAM-fabricated PEEK, acetal, and cobalt-chromium (Co-Cr) frameworks in removable partial dentures (RPDs). Methods Forty-five frameworks were fabricated (15 each of PEEK, acetal, and Co-Cr) and tested for retentive forces using a universal testing machine at a crosshead speed of 5 mm/min. The frameworks were divided into three groups: one with digitally milled PEEK, one with Co-Cr, and one with digitally milled acetal. Each partial denture clasp was designed using CAD/CAM software, extending between the central incisor and the second premolar. These clasps were specifically designed to aid in securing the framework during tensile testing and to facilitate the removal of cast clasps during later stages. Results PEEK frameworks demonstrated the highest retentive forces (mean: 3.52 ± 0.78 N, p < 0.001), followed by acetal (mean: 0.47 ± 0.02 N) and Co-Cr (mean: 0.32 ± 0.12 N). Conclusions PEEK outperformed other materials, making it a promising candidate for RPD frameworks.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-12-23
DOI
https://doi.org/10.7759/cureus.76269
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Retentive Forces in Three Types of Removable Partial Denture Framework Materials: An In Vitro Study

Ribaz Tahsin Kakai
Cureus
Dental materials and restorations
article

Evaluation of Retentive Forces in Three Types of Removable Partial Denture Framework Materials: An In Vitro Study

Ribaz Tahsin Kakai
article en

Abstract

Introduction The utilization of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in the production of polyetheretherketone (PEEK) and acetal frameworks enhances the precision and stability of partial denture frameworks. This study evaluates the retentive forces of CAD/CAM-fabricated PEEK, acetal, and cobalt-chromium (Co-Cr) frameworks in removable partial dentures (RPDs). Methods Forty-five frameworks were fabricated (15 each of PEEK, acetal, and Co-Cr) and tested for retentive forces using a universal testing machine at a crosshead speed of 5 mm/min. The frameworks were divided into three groups: one with digitally milled PEEK, one with Co-Cr, and one with digitally milled acetal. Each partial denture clasp was designed using CAD/CAM software, extending between the central incisor and the second premolar. These clasps were specifically designed to aid in securing the framework during tensile testing and to facilitate the removal of cast clasps during later stages. Results PEEK frameworks demonstrated the highest retentive forces (mean: 3.52 ± 0.78 N, p < 0.001), followed by acetal (mean: 0.47 ± 0.02 N) and Co-Cr (mean: 0.32 ± 0.12 N). Conclusions PEEK outperformed other materials, making it a promising candidate for RPD frameworks.

CureusVol. 16(12)
Kurdistan Regional Government (IQ), University of Kurdistan Hewler (IQ)
Industry, innovation and infrastructure
Openalex Percentile: Top 72%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.