DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY

This study suggests an asymmetric multilevel inverter based on DSTATCOM that employs SVPWM techniques to produce higher output levels. There are two steps in the suggested inverter. One full bridge and two half bridges make up the inverter's main stage. A full bridge converter had four switches and a single DC source, while half bridges have separate DC sources with a voltage ratio of 1:3:3. Every cell has a fixed neutral point and is connected in a cascaded fashion. The inverter's performance is not improved by setting the DC source values equally. A folded cascaded H-bridge circuit running at a line frequency makes up the second circuit. Control plan PWM's space vector modulation was used to verify the suggested topology. Each control scheme's specific methodology as well as switching pulses are covered in great detail. In MATLAB/Simulink, the suggested system has been simulated with an output voltage of 350 V and an output current of roughly 3.5 A.

Authors

Institutions

Publication Details

Journal
Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska
Published
2024-12-21
DOI
https://doi.org/10.35784/iapgos.6355
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY

Govindasamy Saravana Venkatesh, Panneerselvam Sundaramoorthi
Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska
Multilevel Inverters and Converters
article

DSTATCOM-BASED 15 LEVEL ASYMMETRICAL MULTILEVEL INVERTER FOR IMPROVING POWER QUALITY

Govindasamy Saravana Venkatesh, Panneerselvam Sundaramoorthi
article en

Abstract

This study suggests an asymmetric multilevel inverter based on DSTATCOM that employs SVPWM techniques to produce higher output levels. There are two steps in the suggested inverter. One full bridge and two half bridges make up the inverter's main stage. A full bridge converter had four switches and a single DC source, while half bridges have separate DC sources with a voltage ratio of 1:3:3. Every cell has a fixed neutral point and is connected in a cascaded fashion. The inverter's performance is not improved by setting the DC source values equally. A folded cascaded H-bridge circuit running at a line frequency makes up the second circuit. Control plan PWM's space vector modulation was used to verify the suggested topology. Each control scheme's specific methodology as well as switching pulses are covered in great detail. In MATLAB/Simulink, the suggested system has been simulated with an output voltage of 350 V and an output current of roughly 3.5 A.

Informatyka Automatyka Pomiary w Gospodarce i Ochronie ŚrodowiskaVol. 14(4)
Periyar Maniammai Institute of Science & Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 78%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.