STUDY OF THE OZONE CONTROL PROCESS USING ELECTRONIC SENSORS

In research work the problem of studying the process of ozone control with the help of electronic sensors is considered. In research work, special sensors were used, which are formed around coronary electrodes in the ozonator and to monitor the concentration of ozone in the room. This is because ozone is known to adversely affect human health if its maximum permissible air concentration exceeds 0.16 mg/m3. A small system of ozonators was developed in a special laboratory, theoretical and experimental tests were carried out. In practice, the obtained data and the electric diagram of the ozonator (on the ARDUINO platform) were collected. "Prana Air" sensors and current sensors were used to accurately determine the ozone (O3) concentration around the ozone nozzle to measure the current at the electrodes.

Authors

Institutions

Publication Details

Journal
Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska
Published
2024-12-21
DOI
https://doi.org/10.35784/iapgos.6051
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STUDY OF THE OZONE CONTROL PROCESS USING ELECTRONIC SENSORS

Sunggat Marxuly, Нуржигит Смайлов, Аскар Абдыкадыров, K. S. Chezhimbayeva
Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska
Air Quality Monitoring and Forecasting
article

STUDY OF THE OZONE CONTROL PROCESS USING ELECTRONIC SENSORS

Sunggat Marxuly, Нуржигит Смайлов, Аскар Абдыкадыров, K. S. Chezhimbayeva
article en

Abstract

In research work the problem of studying the process of ozone control with the help of electronic sensors is considered. In research work, special sensors were used, which are formed around coronary electrodes in the ozonator and to monitor the concentration of ozone in the room. This is because ozone is known to adversely affect human health if its maximum permissible air concentration exceeds 0.16 mg/m3. A small system of ozonators was developed in a special laboratory, theoretical and experimental tests were carried out. In practice, the obtained data and the electric diagram of the ozonator (on the ARDUINO platform) were collected. "Prana Air" sensors and current sensors were used to accurately determine the ozone (O3) concentration around the ozone nozzle to measure the current at the electrodes.

Informatyka Automatyka Pomiary w Gospodarce i Ochronie ŚrodowiskaVol. 14(4)
Satbayev University (KZ), Almaty University of Power Engineering and Telecommunications (KZ)
Openalex Percentile: Top 79%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

STUDY OF THE OZONE CONTROL PROCESS USING ELECTRONIC SENSORS — Sunggat Marxuly, Нуржигит Смайлов, et al. · Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska (2024) | TGRS Research Map | TGRS