Characterization of Ring Resonators for Ultrasound Sensing in a 45 nm Monolithic SPCLO Process

Monolithic integration of electronics and photonics enables low-power, high-density ultrasound receiver arrays based on silicon microring resonators (MRRs). This paper presents an array of MRRs fabricated in a high-volume 45 nm electronics-photonics CMOS-SOI process. We review a range of MRR-based sensors with different waveguide geometries, characterizing each sensor type electro-optically; we further evaluate sensitivity to ultrasound with and without the presence of undercut structures. The best performance is achieved using an undercut adiabatic microring resonator, which has an average intrinsic sensitivity to ultrasound of $23.63 \mathrm{fm} / \mathrm{kPa}$ at 15 MHz with a standard deviation of $11.97 \mathrm{fm} / \mathrm{kPa}$, while alternative ring geometries achieve comparable performance.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798151
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of Ring Resonators for Ultrasound Sensing in a 45 nm Monolithic SPCLO Process

Manuj Singh, Vladimir Stojanović, Panagiotis Zarkos, Sarika Madhvapathy et al.
Acoustic Wave Resonator Technologies
article

Characterization of Ring Resonators for Ultrasound Sensing in a 45 nm Monolithic SPCLO Process

Manuj Singh, Vladimir Stojanović, Panagiotis Zarkos, Sarika Madhvapathy, Danielius Kramnik
article en

Abstract

Monolithic integration of electronics and photonics enables low-power, high-density ultrasound receiver arrays based on silicon microring resonators (MRRs). This paper presents an array of MRRs fabricated in a high-volume 45 nm electronics-photonics CMOS-SOI process. We review a range of MRR-based sensors with different waveguide geometries, characterizing each sensor type electro-optically; we further evaluate sensitivity to ultrasound with and without the presence of undercut structures. The best performance is achieved using an undercut adiabatic microring resonator, which has an average intrinsic sensitivity to ultrasound of $23.63 \mathrm{fm} / \mathrm{kPa}$ at 15 MHz with a standard deviation of $11.97 \mathrm{fm} / \mathrm{kPa}$, while alternative ring geometries achieve comparable performance.

Boston University (US), Lawrence Berkeley National Laboratory (US), University of California, Berkeley (US)
National Science Foundation
Affordable and clean energy
Openalex Percentile: Top 78%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.