LSTM-based ECG Signal Classification with Multi-level One-hot Encoding for Wearable Applications

This paper presents an electrocardiogram (ECG) signal classification method using one-hot coding scheme and Long Short-Term Memory (LSTM) neural network. Instead of the conventional analog to digital converter (ADC) with two’s complement binary output, one-hot encoding scheme is adopted in this design to convert the analog signal to 1D vector and then further processed by a LSTM network for classification. Our study shows that one-hot encoding can effectively represent the features of ECG signal with low data bit-width and sampling rate. The proposed method not only simplifies the ADC design, but also improves the classification accuracy. Simulation results show that the proposed design only requires 5-bit bit-width with 50 Hz sampling rate to achieve 96.9% validation accuracy on 5-class classification task using MIT-BIH ECG dataset.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798273
Citations
2
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LSTM-based ECG Signal Classification with Multi-level One-hot Encoding for Wearable Applications

Wang Ling Goh, Jinhai Hu, Yuan Gao
2 citations
ECG Monitoring and Analysis
0.80
article

LSTM-based ECG Signal Classification with Multi-level One-hot Encoding for Wearable Applications

Wang Ling Goh, Jinhai Hu, Yuan Gao
article en
2 citations

Abstract

This paper presents an electrocardiogram (ECG) signal classification method using one-hot coding scheme and Long Short-Term Memory (LSTM) neural network. Instead of the conventional analog to digital converter (ADC) with two’s complement binary output, one-hot encoding scheme is adopted in this design to convert the analog signal to 1D vector and then further processed by a LSTM network for classification. Our study shows that one-hot encoding can effectively represent the features of ECG signal with low data bit-width and sampling rate. The proposed method not only simplifies the ADC design, but also improves the classification accuracy. Simulation results show that the proposed design only requires 5-bit bit-width with 50 Hz sampling rate to achieve 96.9% validation accuracy on 5-class classification task using MIT-BIH ECG dataset.

Agency for Science, Technology and Research (SG), Nanyang Technological University (SG), Institute of Microelectronics (SG)
Openalex Percentile: Top 22%
ECG Monitoring and Analysis
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.