The Role of Strapping Forces on Human Exoskeleton Interaction Pressure - A Pilot Study

The study of physical human-exoskeleton interaction (pHEI) has been largely unexplored due to rapid technological advancements in the field and the challenges in quantifying these interactions. Accurately measuring and assessing interaction pressure poses significant technical challenges, including reliably estimating contact area and pressure distribution during motion, as well as interpreting these pressure values in terms of user safety. This study aims to address these challenges by investigating the effects of different strapping forces and joint misalignments on interaction pressure and contact area during exoskeleton use. Various tests under different misalignment and strapping force levels were conducted on an instrumented dummy limb to ensure consistent testing conditions. Results indicate that strapping forces and misalignments significantly impact pressure peaks and contact area, underscoring the difficulty in generalizing safety thresholds. This research bridges gaps in pHEI pressure measurements and supports the development of safer exoskeleton technologies. It also focuses on the crucial aspect of safely attaching exoskeletons to the human body, emphasizing the importance of controlling initial attachment conditions.

Authors

Institutions

Publication Details

Published
2024-11-06
DOI
https://doi.org/10.1109/robot61475.2024.10796872
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Role of Strapping Forces on Human Exoskeleton Interaction Pressure - A Pilot Study

Stefano Massardi, Juan C. Moreno, David Rodriguez-Cianca, Matteo Lancini et al.
Prosthetics and Rehabilitation Robotics
article

The Role of Strapping Forces on Human Exoskeleton Interaction Pressure - A Pilot Study

Stefano Massardi, Juan C. Moreno, David Rodriguez-Cianca, Matteo Lancini, Diego Torricelli
article en

Abstract

The study of physical human-exoskeleton interaction (pHEI) has been largely unexplored due to rapid technological advancements in the field and the challenges in quantifying these interactions. Accurately measuring and assessing interaction pressure poses significant technical challenges, including reliably estimating contact area and pressure distribution during motion, as well as interpreting these pressure values in terms of user safety. This study aims to address these challenges by investigating the effects of different strapping forces and joint misalignments on interaction pressure and contact area during exoskeleton use. Various tests under different misalignment and strapping force levels were conducted on an instrumented dummy limb to ensure consistent testing conditions. Results indicate that strapping forces and misalignments significantly impact pressure peaks and contact area, underscoring the difficulty in generalizing safety thresholds. This research bridges gaps in pHEI pressure measurements and supports the development of safer exoskeleton technologies. It also focuses on the crucial aspect of safely attaching exoskeletons to the human body, emphasizing the importance of controlling initial attachment conditions.

Centre for Automation and Robotics (ES), University of Brescia (IT)
Climate action
Openalex Percentile: Top 78%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.