An Equivalent Circuit Model of Living Myocardial Slice Cultured on Microelectrode Array with in-vitro Experimental Validations

In this paper, we present an equivalent circuit model that integrates a living myocardial slice (LMS) cultured on a microelectrode array (MEA) to effectively simulates a heart-on-a-chip (HoC) within Electronic Design Automation (EDA) software. The cardiac fiber model consists of cardiomyocytes interconnected by gap junctions to simulate the action potential (AP) conduction in the longitudinal direction. We systematically explored several parameters, including gap junction resistors, seal resistors, and electrode diameters, to assess their effects on local field potential (LFP). The model accuracy was validated through in vitro experiments using mouse LMS, confirming its potential for guiding HoC design in cardiac research.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798316
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Equivalent Circuit Model of Living Myocardial Slice Cultured on Microelectrode Array with in-vitro Experimental Validations

Zhenyu Gao, Sijun Du, Rui Guan, Natasja M.S. de Groot et al.
3D Printing in Biomedical Research
article

An Equivalent Circuit Model of Living Myocardial Slice Cultured on Microelectrode Array with in-vitro Experimental Validations

Zhenyu Gao, Sijun Du, Rui Guan, Natasja M.S. de Groot, Robert van Veldhoven, F. Widdershoven, Tao Shen, Yannick J.H.J. Taverne, Paul Knops
article en

Abstract

In this paper, we present an equivalent circuit model that integrates a living myocardial slice (LMS) cultured on a microelectrode array (MEA) to effectively simulates a heart-on-a-chip (HoC) within Electronic Design Automation (EDA) software. The cardiac fiber model consists of cardiomyocytes interconnected by gap junctions to simulate the action potential (AP) conduction in the longitudinal direction. We systematically explored several parameters, including gap junction resistors, seal resistors, and electrode diameters, to assess their effects on local field potential (LFP). The model accuracy was validated through in vitro experiments using mouse LMS, confirming its potential for guiding HoC design in cardiac research.

NXP (Netherlands) (NL), Erasmus MC (NL), Delft University of Technology (NL)
Delta
Openalex Percentile: Top 78%
3D Printing in Biomedical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Equivalent Circuit Model of Living Myocardial Slice Cultured on Microelectrode Array with in-vitro Experimental Validations — Zhenyu Gao, Sijun Du, et al. · (2024) | TGRS Research Map | TGRS