An Energy-Efficient Adaptive-Frequency-Modulated PPG Acquisition Circuits with Power-on-Demand Trans-impedance Amplifier

Photoplethysmoggraphy (PPG) is a non-invasive technique used to detect blood volume changes in the microvascular bed of issues. It is commonly used in wearable devices and medical monitoring systems to measure heart several vital signs, such as blood oxygen saturation, blood preasure and heart rate. Frequency modulation (FM) is one of the efficiency approaches to mitigate the SNR degeneration due to motion artifacts. However, FM results in higher required bandwidth in the acquisition circuits which leads to a higher overhead in power consumption, especially when remaining stationary for extended periods. In this paper, an adaptive-frequency-modulated scheme together with a power-on-demand trans-impedance amplifier (TIA) is proposed. Which enables a power-on-demand strategy to maintain sufficient SNR with minimum modulation frequency as well as the circuit bandwidth. The experimental results shows a 37% power saving in typical scenarios compared to conventional fixed-frequency PPG acquisition circuits.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798221
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Energy-Efficient Adaptive-Frequency-Modulated PPG Acquisition Circuits with Power-on-Demand Trans-impedance Amplifier

Xiafan Gu, Yuan Jiang, Yuwei Huang, Jian Zhao et al.
Analog and Mixed-Signal Circuit Design
article

An Energy-Efficient Adaptive-Frequency-Modulated PPG Acquisition Circuits with Power-on-Demand Trans-impedance Amplifier

Xiafan Gu, Yuan Jiang, Yuwei Huang, Jian Zhao, Biao Huang, Yongfu Li
article en

Abstract

Photoplethysmoggraphy (PPG) is a non-invasive technique used to detect blood volume changes in the microvascular bed of issues. It is commonly used in wearable devices and medical monitoring systems to measure heart several vital signs, such as blood oxygen saturation, blood preasure and heart rate. Frequency modulation (FM) is one of the efficiency approaches to mitigate the SNR degeneration due to motion artifacts. However, FM results in higher required bandwidth in the acquisition circuits which leads to a higher overhead in power consumption, especially when remaining stationary for extended periods. In this paper, an adaptive-frequency-modulated scheme together with a power-on-demand trans-impedance amplifier (TIA) is proposed. Which enables a power-on-demand strategy to maintain sufficient SNR with minimum modulation frequency as well as the circuit bandwidth. The experimental results shows a 37% power saving in typical scenarios compared to conventional fixed-frequency PPG acquisition circuits.

Shanghai Jiao Tong University (CN), Shanghai Children's Medical Center (CN)
Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 78%
Analog and Mixed-Signal Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Energy-Efficient Adaptive-Frequency-Modulated PPG Acquisition Circuits with Power-on-Demand Trans-impedance Amplifier — Xiafan Gu, Yuan Jiang, et al. · (2024) | TGRS Research Map | TGRS