A 4.4μW Cuffless Blood Pressure Measurement Processor Based on Event-Driven and Module-Level Asynchronous Scheme

This paper proposes a cuffless blood pressure measurement processor based on photoplethysmogram (PPG) signals and deep neural networks (DNN). To reduce system power consumption, a module-level asynchronous scheme is designed. Moving average filter, feature extraction, and DNN computation units are all driven sequentially using event-driven wake-up. The moving average filtering unit is driven by a signal detector, which consists of a comparator and a counter. Each unit operates at different frequencies, effectively reducing the overall power consumption. The processor achieves mean error of $4.9 \pm 6.2$ mmHg and $3.4 \pm 4.4 \mathrm{mmHg}$ for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. Designed with a standard 55 nm CMOS technology, the digital core occupies an area of $0.64 \mathrm{~mm}^{2}$, operates at a voltage of 1.2 V, with an estimated power consumption of $4.4 \mu \mathrm{~W}$.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798356
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 4.4μW Cuffless Blood Pressure Measurement Processor Based on Event-Driven and Module-Level Asynchronous Scheme

Zhuoqi Guo, Youze Xin, Ming-Jye Sheng, Bing Zhang et al.
1 citations
ECG Monitoring and Analysis
0.40
article

A 4.4μW Cuffless Blood Pressure Measurement Processor Based on Event-Driven and Module-Level Asynchronous Scheme

Zhuoqi Guo, Youze Xin, Ming-Jye Sheng, Bing Zhang, Rui Xing, Zhongming Xue, Geng Li
article en
1 citations

Abstract

This paper proposes a cuffless blood pressure measurement processor based on photoplethysmogram (PPG) signals and deep neural networks (DNN). To reduce system power consumption, a module-level asynchronous scheme is designed. Moving average filter, feature extraction, and DNN computation units are all driven sequentially using event-driven wake-up. The moving average filtering unit is driven by a signal detector, which consists of a comparator and a counter. Each unit operates at different frequencies, effectively reducing the overall power consumption. The processor achieves mean error of $4.9 \pm 6.2$ mmHg and $3.4 \pm 4.4 \mathrm{mmHg}$ for systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. Designed with a standard 55 nm CMOS technology, the digital core occupies an area of $0.64 \mathrm{~mm}^{2}$, operates at a voltage of 1.2 V, with an estimated power consumption of $4.4 \mu \mathrm{~W}$.

Xi'an Jiaotong University (CN)
Openalex Percentile: Top 29%
ECG Monitoring and Analysis
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 4.4μW Cuffless Blood Pressure Measurement Processor Based on Event-Driven and Module-Level Asynchronous Scheme — Zhuoqi Guo, Youze Xin, et al. · (2024) | TGRS Research Map | TGRS