A 12b Dual-Mode SAR ADC for Bio-Medical Applications

This paper presents an ultra-low power 12b successive-approximation register (SAR) analog-to-digital converter (ADC) for bio-medical sensing analog front-end circuits. This ADC used binary-window and capacitor-swapping schemes to improve its linearity. A time-domain comparator was proposed to meet both low-noise and low-supply voltage. Some switched-capacitor circuits were applied with thick-oxide transistors against the leakage issue. Furthermore, a bypass-switching function was applied to deal with the sparse biomedical signals for additional power reduction. The 12b SAR ADC was fabricated using $180-\mathrm{nm}$ CMOS technology. This prototype ADC core consumes only 36 nW from $0.5-\mathrm{V}$ and $1.0-\mathrm{V}$ supplies at $1 \mathrm{kS} / \mathrm{s}$. With the Nyquist rate input, the simulated SNDR and SFDR are 68.7 and 83 dB, respectively. The peak ENOB is maintained at 11.1 bits, equivalent to a figure-of-merit of $18 \mathrm{fJ} /$ conversion-step. The sampling frequency can be scaled from 1 kHz to 10 kHz for EEG signal acquisition.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798281
Citations
3
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 12b Dual-Mode SAR ADC for Bio-Medical Applications

J.B. Kuo, Yung‐Hui Chung
3 citations
Analog and Mixed-Signal Circuit Design
0.55
article

A 12b Dual-Mode SAR ADC for Bio-Medical Applications

J.B. Kuo, Yung‐Hui Chung
article en
3 citations

Abstract

This paper presents an ultra-low power 12b successive-approximation register (SAR) analog-to-digital converter (ADC) for bio-medical sensing analog front-end circuits. This ADC used binary-window and capacitor-swapping schemes to improve its linearity. A time-domain comparator was proposed to meet both low-noise and low-supply voltage. Some switched-capacitor circuits were applied with thick-oxide transistors against the leakage issue. Furthermore, a bypass-switching function was applied to deal with the sparse biomedical signals for additional power reduction. The 12b SAR ADC was fabricated using $180-\mathrm{nm}$ CMOS technology. This prototype ADC core consumes only 36 nW from $0.5-\mathrm{V}$ and $1.0-\mathrm{V}$ supplies at $1 \mathrm{kS} / \mathrm{s}$. With the Nyquist rate input, the simulated SNDR and SFDR are 68.7 and 83 dB, respectively. The peak ENOB is maintained at 11.1 bits, equivalent to a figure-of-merit of $18 \mathrm{fJ} /$ conversion-step. The sampling frequency can be scaled from 1 kHz to 10 kHz for EEG signal acquisition.

National Taiwan University of Science and Technology (TW)
Affordable and clean energy
Openalex Percentile: Top 35%
Analog and Mixed-Signal Circuit Design
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 12b Dual-Mode SAR ADC for Bio-Medical Applications — J.B. Kuo, Yung‐Hui Chung · (2024) | TGRS Research Map | TGRS