A Fast Square Wave-based Electrochemical Impedance Spectroscopy for Impedance-based Biomedical Applications

This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), in order to meet the requirements of portable, real-time biomedical impedance-based detections. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the sensor excitation signal. This approach achieves a fast EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. The conditions where the sensor behaves like a pseudo electronic Linear Time-Invariance (LTI) circuit are firstly identified by investigating its large-signal behavior, Cyclic Voltammetry (CV), which ensures the sensor shows no potential-amplitude dependence, hence also providing possibilities for other novel EIS circuitry. A circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS to implement this methodology for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 1.48% average Mean Absolute Percentage Error (MAPE), compared to a commercial chemical instrument AutoLab, which ensures this method is suitable for portable, real-time EIS biomedical detections and applications.

Authors

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/biocas61083.2024.10798397
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fast Square Wave-based Electrochemical Impedance Spectroscopy for Impedance-based Biomedical Applications

Daniel O’Hare, Alan O’Riordan, Han Shao, Zhongzheng Wang et al.
Analytical Chemistry and Sensors
article

A Fast Square Wave-based Electrochemical Impedance Spectroscopy for Impedance-based Biomedical Applications

Daniel O’Hare, Alan O’Riordan, Han Shao, Zhongzheng Wang, Ivan O’Connell, Javier Higes-Marquez
article en

Abstract

This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), in order to meet the requirements of portable, real-time biomedical impedance-based detections. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the sensor excitation signal. This approach achieves a fast EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. The conditions where the sensor behaves like a pseudo electronic Linear Time-Invariance (LTI) circuit are firstly identified by investigating its large-signal behavior, Cyclic Voltammetry (CV), which ensures the sensor shows no potential-amplitude dependence, hence also providing possibilities for other novel EIS circuitry. A circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS to implement this methodology for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 1.48% average Mean Absolute Percentage Error (MAPE), compared to a commercial chemical instrument AutoLab, which ensures this method is suitable for portable, real-time EIS biomedical detections and applications.

Science Foundation Ireland
Affordable and clean energy
Openalex Percentile: Top 74%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.